M Design LUNA HC Series Скачать руководство пользователя страница 13

13

 

 

6

 

SUPLIED ACCESSORIES 

 

door opener 1pc 

 

hub 5 pc 

 

taker of ash 1pc 

 

operating instrctions, guarrantee and certificate of quality and completeness of the product 

 

Warning!!!

  

The  correct  and  safe  operation  of  the  fireplace  furnace  type  series  „LUNA“  it  is  imperative  to 
observe the operating instructions and installation!!! 

7

 

SIGN  

Identification of the type of fireplace type „LUNA HC“ is as follows: 

-

 

manufacturer: HT design, s.r.o.,  01318 Podhorie 71, Slovensko 

-

 

type : „LUNA ...... HC “,  

-

 

usable power range: 10 kW 

-

 

heat flow into the space: 10 kW 

-

 

standard :  STN EN 13229 

-

 

keep operating instructions  

-

 

the unit can be connected to a common chimney 

-

 

use only recommended fuels  

-

 

the appliance is designed for: shor-term operation 

-

 

serial number/see Pic.18/ 

TYPE- fireplace 

 700 HC 

 900 HC 

   1100 HC 

Rated thermal power  (kW) 

10 

11 

Average efficiency  (%) 

78 

78 

78 

Heat flow into the space (kW) 

10 

11 

Power range (kW) 

5 - 11 

5 - 12 

6 - 13 

Flue gas temperature at rated output (°C) 

195 

195 

195 

Avg. CO concentration at 13%  O2        
                         (%) 

0,10 

0,10 

0,10 

The average volume concentration of CO at 
13% O2     (mg.m-3) 

1200 

1200 

1200 

Minimum blast (Pa) 

12 

12 

12 

The weight of the fireplace furnace (kg) 

280 

300 

330 

Minimum distance from flammable 
materials from the flanks and rear of                              
(mm) 

300 

300 

300 

Minimum distance from flammable 
materials from the front

                      

(mm)                                                               

1000 

1000 

1000 

Fuel delivery interval  (h) 

Recommeded fuel – dry  wood 

Beech, oak, spruce 

Consumption of fuel at usable power range 
(kg/h)

 

3,2 

 

3,5 

3,7 

123456 

Pic.18 

Содержание LUNA HC Series

Страница 1: ...COLLECTION LUNA HC INSTRUCTION FOR INSTALLATION AND USE...

Страница 2: ...ALS LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 4 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATON THE FIREPLACE MODE...

Страница 3: ...e optimal function of the stove output clear glass etc The ideal is to use dried wood with moisture content 12 to 18 Damp wood gives off less heat clogs the chimmey and the glass of the fireplace s do...

Страница 4: ...ibes rules and local regulations The device must be built in an area with an adequate capacity on on the board which can spread the weight of the device The device must be positioned so as to maintain...

Страница 5: ...qualified person to deliver state of the chimney and flue for their safe and reliable operation 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR In the place of installation firepla...

Страница 6: ...INSTRUCTIONS QUIPMENT MAY OVERHEAT Once installation is omplete the device may be doing the surround If you check everything you can to make a final insulating and finishing operations Make sure the d...

Страница 7: ...N AIR INTAKES Any type of combustion using air If enclosure is an additional air supply is very important It is very important always to avoid creating negative pressure inside the room Need air intak...

Страница 8: ...red to be in the room does not produce any vacuum Grid in the floor sucking cold air pic 12 Do not connect it through a tube The air itself will find a way to get to the right place If it is possible...

Страница 9: ...andard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert LUNA HC can connect from the top Pic 13a or the bac...

Страница 10: ...controls the front bar see pic 14a by help of key pic 14b By controllin the flow of air to control your heater secondary primary pic 15 Open the door control doees not affect the combustion Pic 14b Pi...

Страница 11: ...nd then bursts when the fire start 4 1 MAINTANCE in addition to regular cleaning of glass must be your chimney at least once a year sweep to insert optimal function It s not just a legal requirement b...

Страница 12: ...ation When operating the fireplace furnace type series LUNA rise to the surface of the walls of high temperature at which it could be burning It is therefore prohibited during the operation touch the...

Страница 13: ...e only recommended fuels the appliance is designed for shor term operation serial number see Pic 18 TYPE fireplace 700 HC 900 HC 1100 HC Rated thermal power kW 9 10 11 Average efficiency 78 78 78 Heat...

Страница 14: ...14 8 SERIE SIZE...

Страница 15: ...15 9 SPARE PARTS Luna HC...

Страница 16: ...16 SPARE PARTS Luna HC...

Страница 17: ...17 SPARE PARTS Luna HC...

Страница 18: ...18...

Страница 19: ...s inappropriate improper placement and the inevitable damage caused by the event natural disaster etc 4 The guarranty also does not apply to damages caused indirectly and damage or personal injury cas...

Отзывы: