M Design LUNA GOLD+ COLLECTION Скачать руководство пользователя страница 10

INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+  WOOD

Tabel N°1. Warm air outlet

with fan

without fan

Luna Gold 700 H 

2

2

Luna Gold 850 H

2

2

Luna Gold 1000H

2

4

  Luna Gold 1150 H

  2

  4

  Luna Gold 1300 H

  2 

  4

  Luna Gold 550 V 

  2

  2 

  Luna Gold 850 V

  2

  4

  Luna Gold 1000V / 1150V   2

  4

  Luna Gold 850 DV / DH

  

  2

  Luna Gold 1150 DH

  2

  Luna Gold 1000DV

  

  2

2.6 CONVECTION CURRENT

   

2.6.1 Natural convection

It is compulsory to open 2 or 4 hot air vents (see table 1) at the 

top of the appliance. The entrance for the air supply convection are situated 

at the lower backside of the Luna Gold+ and also through the opening that is 

provided for the fan. These have been constructed in such a way that no air can 

be blown out along here, not even with a fan. The stove is placed at least 20 mm 

above the floor (if placed on the floor) to allow for natural convection.

A clearance of at least 4 dm3  , excluding the measurements of a dust filter, or at 

least 6 dm3 , including the measurements of a filter, must be provided for in the 

masonry. (Note: Remember to take the measurements of the clearance of the

grids into account.) (Pic.7a)

    

2.6.2 Convection by means of a fan (optional)

It is compulsory to open at least 2 hot air vents (see table 1). It is essential to 

separate the air supply ducts and the air vents correctly in the masonry. Some 

insulation material gets damaged in time, and it is essential to separate it from 

the ventilation air supply, otherwise one runs the risk that it is sucked in and 

spread in the house. It is therefore also advisable to use fixed insulation plates 

(Promatec, HT-platen or promatec). The fan may be mounted either on the out

-

side or on the inside, which even makes it possible to install a fan afterwards.

    

2.6.3 Hot air ducts

Thermally insulated ducts are essential for the optimal functioning of the ap-

pliance (these cause ‘draught’ in the convection air current). By using the maxi

-

mum number of ducts (at least 2), the output is improved and the noise (that is 

caused by the displacement) is reduced.

For the purposes of the installation of these ducts it is best to go vertically up-

wards first for at least 1m and then to change direction, making a rather wide 

bend and avoid using a flue terminal grid with a small clearance because the 

speed loss that this causes reduces the efficiency of the hot air vents. 

M-design has developed its ideal hot air grids which have many advantages 

(Pic 7b and 7c)

Pic. 7b 

Entrance convection

air ( at backside )

Pic. 7a 

10

Содержание LUNA GOLD+ COLLECTION

Страница 1: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD LUNA GOLD COLLECTION INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 08 2011...

Страница 2: ...N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I N G A...

Страница 3: ...2 6 2 Convection generated by a fan optional 2 6 3 Hot air ducts 2 7 FAN 12 2 7 1 Installation 2 7 2 Fan dimmer 2 8 FLUE 13 2 8 1 Flue 2 9 HOW TO REGULATE FIREPLACE IN SENSE OF DROUGHT 14 2 9 1 Baffl...

Страница 4: ...he stove output clear glass etc Good quality wood is wood that has been dried under an aerated shelter for at least 2 years 18 moisture content Damp wood gives off less heat and dirties the stove and...

Страница 5: ...rden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room CAUTION It is...

Страница 6: ...s and conditions of our contract of guarantee Ask your supplier for advice pic 1 pic 2 pic 3 A min 3 5 cm B 14 5 cm C min 18 cm 2 2 POSITIONING THE FIREPLACE Place the fireplace on a stable surface us...

Страница 7: ...ing you can perform the final insulating and finishing operations The built in part of the furnace tends to be very warm Please check that the furnace is not too narrowly fitted and that there is adeq...

Страница 8: ...ATTENTION TO LEAVE APPROX 2 MM INBETWEEN THE FRAME AND THE FINISHING MATERIAL HEAT EXPANSION pic 1 pic 2 pic 3 8 Example Finished size of the Luna 1150H Gold is 450 x 1080 mm Thickness 3 sided frame...

Страница 9: ...cted to one of the 4 entrances that are provided on the left right or lower side of the fireplace pic 4 5 Use for this purpose one of five connection pieces pic 6 7 Thanks to this new system the air t...

Страница 10: ...a fan optional It is compulsory to open at least 2 hot air vents see table 1 It is essential to separate the air supply ducts and the air vents correctly in the masonry Some insulation material gets...

Страница 11: ...D WOOD EACH APPERTURE YOU MAKE MUST BE CONNECTED WITH FLEXIBLE Design Grid outlet with 2 connections Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm...

Страница 12: ...at some grids give off more heat than others and seeing that a hot air pipe func tions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even mo...

Страница 13: ...lue and its position are very important One individual flue does not have more than two changes of direction The angle of the corner of these changes of direction may not be greater than 45 with the p...

Страница 14: ...ught The baffle plate is automatically opened when the window is slid open so that no smoke escapes into the living room The plate may be adjusted in 2 ways 2 9 1 1 FIRST SETTING ANGLE BAFFLE PLATE WI...

Страница 15: ...screws to adjust the moving plate nr 1 fig 9e in sence of drough FIG 9e IMPORTANT IF YOU THINK THE DROUGHT IS NOT ENOUGH AND YOU HAVE SOME SMOKE RETURN IN THE LIVINGROOM THEN YOU HAVE TO CHECK FIRST P...

Страница 16: ...nto the livingroom Fig 10 door closed Fig 11 door open 2cm valve on second deflector main valve Installing the deflectors The first deflector 1 exists of two parts A movable part 1a and a fix part 1b...

Страница 17: ...window is regulated automatically with two bimetallic strips At each of the superior corners of the window you ll find two circular magnets Those ensures that the window is closing well against the b...

Страница 18: ...open with the result that the fire will keep burning much more mildly When there is a fire with two lift doors open both the plates will automatically open up completely and therefore there will be n...

Страница 19: ...ir coming into the fireplace Pic 9 When the door is opened the air clapet is also being opened Extra air is going in the fire place trough apertures situated in the 4th side frame direct from the air...

Страница 20: ...ve your chimney swept at least once a year for optimal functioning of the Luna Not only is this a legal requirement but it is also meant for your own safety A fire brick Chamotte can still work perfec...

Страница 21: ...lfunctions linked to Incorrect installation of incorrect connection Chimney draught that has not been adjusted Transport and installation Incorrect usage Insufficient maintenance Unsuitable hazardous...

Страница 22: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 6 SPARE PARTS...

Страница 23: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 7 3 SIDED FRAME...

Страница 24: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 8 4th sided Frame...

Отзывы: