13
Connections
70V/100V
This configuration creates a stereo 70V speaker
zone. (30W/channel) A 70V/100 V system utilizes
speakers with special taps that set the wattage/
volume of each speaker.
70V/100V speaker system are wired using a
daisy-chain configuration where the amp feeds a
speaker, then that speaker connects to the next
speaker and so on.
When setting an 0E-IA1250 zone for 70V/100V,
be sure to accurately calculate the total wattage
required and not exceed the 0E-IA1250 70V/100V
zone’s output, 30W per channel in 70V/100V mode.
Typically 70V amp power requirement can be
calculated by adding the total of the tap wattage
set for all speakers to be connected to a 70V/100V
zone and multiplying it by 1.2. This will allow
roughly a 20% loss of efficiency, typical for this type
of system.
If the total wattage exceeds 30 Watts for a 70/100V
zone, reduce the load to any given zone by
connecting 70V/100V speakers to multiple zones
set to 70V/100V to safely distribute the load.
1. 70V/100V High Voltage Speaker Output -
Set
to 70V if 0E-IA1250 AC Voltage Select switch
Right
Left
Low/Medium Power
70V/100 Speakers
8Ω/4Ω
70V/100V Switch
Set to: 70V/100V
Stereo/Bridged
Switch
Set to: Stereo
70V/100V
-/+ Terminals
Right
Left
Right
Left
70V Speaker
Parallel IN/OUT
70V Speaker
Parallel IN/OUT
IN
OUT
IN
OUT
70V/100V
Distribution Lines
Set 70V/100V
for all 70V/100V
Zones. See text.
is set to 110~120VAC. Set to 100V if 0E-IA1250 AC Voltage Select switch is set to 220~240VAC. This
setting will affect all zones set to 70V/100V.
2. Stereo/Bridged Switch -
Set to the Stereo position.
3. 8Ω/4Ω-70V/100V Switch -
Set to the 70V/100V position.
4. Speaker Connections -
Connect the right 70V distribution line +/- wires to the right 70V/100V
+/- terminals as shown in:
70V/100V Connection.
If configuring stereo, Repeat for the left channel
speaker.
Connect the right c/- distribution lines to the IN terminals on the first 70/100V speaker. Repeat
for the left channel.
Connect the right/left c/- distribution lines to the OUT terminals on the first 70/100V speaker.
Connect the right/left c/- distribution lines to the IN terminals on the next 70/100V speaker.
NOTE 1: Speaker terminals may not be specifically marked IN/OUT.
NOTE 2: In a 70/100V /- polarity is not critical in same way as in a 4/8 Ohm system. But it is
critically important that the connections be consistent, that is, plus to plus, minus to minus.
5. Zone Line IN -
Connect the L & R line level OUT on the zone audio source to the appropriate zone L &
R LINE IN.