7
Setting Toggle Values for the Buttons
The 8 assignable buttons and the pedal can each be assigned to toggle between two values.
This is how:
1. Press the ADVANCED FUNCTION button, followed by the DATA 2 (MIN) key.
2. Type in the Minimum desired toggle number using the numerical data entry keys or the /- buttons.
3. Press the ENTER key to confirm.
4. Press the ADVANCED FUNCTION button, followed by the DATA 3 (MAX) key.
5. Type in Maximum desired toggle number using the numerical data entry keys or the /- buttons.
6. Press the ENTER key to confirm.
If you want the button to send the same value every time, type in the same value both times.
The above method will toggle the button each time you press it. It is also possible to set the button to send one value when you press it, and
another value when you release it. To do this:
1. Press the ADVANCED FUNCTION button, followed by the DATA 1 key.
2. Type in 146 using the numerical data entry keys.
This sets the button up for MIDI CC (On/Off) mode, as shown in Appendix B.
3. Press ENTER to confirm.
4. Assign the two toggle values for press (DATA 3) and release (DATA 2) as described above.
Program Changes
Send out a program change message to the sound card, sound module, instrument or other MIDI device that will receive this standard MIDI
message. The program change will be sent on the global MIDI channel.
1. Press the ADVANCED FUNCTION button. The keyboard will enter Program Mode.
2. Press the PROGRAM key on the keyboard.
3. Type in the program number you wish to send, using the numerical data entry keys, or the
4. /- buttons.
5. Press the ENTER key to confirm.
The assignable buttons can be programmed to send out fixed program messages to individual MIDI channels. For further information
regarding this method, please refer to the “MIDI Messages Explained” section of this manual
Bank Changes
If the receiving device has more than 128 programs, access the additional banks by sending out Bank Change LSB and MSB messages.
1. Press the ADVANCED FUNCTION button. The keyboard will enter Program Mode.
2. Press the BANK LSB or BANK MSB key on the keyboard.
3. Type in the bank number you wish to send, using the numerical data entry keys, or the /- buttons.
4. Press the ENTER key to confirm.
Please check the documentation for your receiving device to ensure that it will respond to these messages.
For more information about LSB and MSB, please refer to the “MIDI Messages Explained” section of this manual.
RPN/NRPN, GM 1&2, Sys Ex and Other Messages
The standard MIDI controller numbers range from 0 to 131. The list of MIDI CC's that can be assigned to the controllers of the keyboard has
been extended to include RPN/NRPN, MMC, and General MIDI 1&2 Sys Ex messages.
These advanced messages are as easily programmed by entering values 132 to154 when programming MIDI CCs. The charts in Appendix B
show which number corresponds to each message.
To program the values required for these advanced messages, press the ADVANCED FUNCTION button to enter Program Mode. After
entering Program Mode, press the DATA 1, DATA 2 or DATA 3 button. For more information, please refer to Appendix B.
Содержание O2