background image

CODEC SAMPLE RATE: This section is enabled only when the board is set to use
the internal crystal (Internal Xtal) as the source of its master clock.  It is disabled
(greyed-out) when the master clock is set to S/PDIF In.  This section indicates the
present board sample rate, as set by application software.  The sample rate selected
here will be used to drive the digital mixer and all outputs.  The "Rate Locked"
checkbox is used to force a sample rate upon the system.  It is disabled by default to
allow software access to all supported sample rates.  When checked, it causes the
driver to only operate at the selected sample rate.  This means that any application
that attempts to open the Delta DiO driver at a sample rate other than the one select-
ed here will fail to do so.  "Reset Rate When Idle" is selected when you want the
sample rate to return to a particular setting when a software application is not active-
ly using the board.  This is particularly handy for keeping the digital mixer running
at a specific rate.  

NOTE: Because the digital monitor mixer runs at the sample rate
of the rest of the board, and because sample rate directly affects
frequency response, it may be desirable to keep the sample rate
at or above 44.1 kHz while using the monitor mixer.

This is

accomplished by enabling "Reset Rate When Idle" and selecting
a sample rate of 44.1 kHz or greater.

S/PDIF SAMPLE RATE: This section is enabled only when the board is set to use
S/PDIF In as the source of its master clock.  It is disabled (greyed-out) when the
master clock is set to internal crystal.  When S/PDIF In is used as the master clock,
the software applications need to be manually informed of the S/PDIF Input sample
rate.  You should select the sample rate closest to that of the S/PDIF source.  While
‘S/PDIF In’ is the master clock source, and you have a sample rate selected here, the
software application(s) using the Delta DiO will be prevented from selecting any
other sample rate. 

NOTE: When S/PDIF In is the master clock source, the digital mon-
itor mixer will run at the sample rate received at the S/PDIF In.
This may or may not adversely affect the frequency response of
the digital mixer.

MULTITRACK DRIVER DEVICES: The Delta DiO drivers are intelligent enough
to synchronize the beginning of recording and playback across all audio devices on
the board.  When using application software that is capable of using multiple chan-
nels simultaneously, select "Single and In-Sync" to ensure that all four output chan-
nels will begin playback at the same time.  Otherwise select "Independent" to allow
the output channels to play independently.  This may be desirable if more than one
application needs to access different DiO channels at the same time.

DMA BUFFER SIZES: This section allows you to specify the amount of system
memory dedicated to buffering digital audio. Setting a buffer size that is too small
may result in clicks or pops in the audio stream as some data may be lost.  Larger
buffers cause slightly more latency but prevent the pops and clicks that might occur
with smaller buffer sizes – the default settings are recommended but you may desire
to tweak these default settings to suit your tastes.

13

Содержание Delta DiO 2496

Страница 1: ...s 95 Installation 7 Windows Driver Configuration 7 Delta Theory of Operation 8 The Digital Monitor Mixer 8 Synchronization 8 Using Delta DiO 2496 with your Software Application 8 Delta DiO 2496 Contro...

Страница 2: ...O available up to 24bit data width and any sampling rate from 8kHz to 96kHz Record a digital audio signal from your DAT MiniDisc CD or external A D converter via one of the Delta DiO s S PDIF inputs...

Страница 3: ...evels Built in digital mixer allows the D A converter to monitor digital inputs act as its own independent stereo output or as a mixture of both Measured D A specs 101dB A weighted dynamic range 0 002...

Страница 4: ...ight line level signals to your monitoring or mix down device The signal lev els for each output may be set to 4dBu or 10dBV via jumpers on the PCI card Quick Guide to Getting Started Here is a list o...

Страница 5: ...uter in order to dissipate any static elec tricity your body may have accumulated You might want to pick up a ground ing wrist strap available from electronics stores like Radio Shack if you want to b...

Страница 6: ...ill give you a selection of locations to search Make sure that Floppy disk drives is checked or click on the check box to do so Insert the Delta DiO 95 98 Driver Software disk into your floppy drive C...

Страница 7: ...sk Once this process completes itself your Delta DiO will be ready for action After completion of the driver installation Windows 95 may require you to restart Windows If it does request a restart rem...

Страница 8: ...s operate at the same sample rate Most of the time the master clock is taken from the Delta DiO s internal crystal oscillators However the S PDIF In may be receiving a data stream that is completely a...

Страница 9: ...lta DiO input and output devices of your choice Delta DiO 2496 Control Panel Software Once your Delta DiO 2496 is properly installed in your system you will see a M Audio Delta H W icon in your Window...

Страница 10: ...f the 36 bit resolution built into the mixer hardware MIXER INPUTS The Mixer Inputs are inputs to the monitor mixer These inputs are hardware audio streams and software audio streams combined to make...

Страница 11: ...sources 1 The default setting WavOut 1 2 connects the DiO s analog outputs to your music software or Windows multimedia applet In other words when music software plays audio to the device named Delta...

Страница 12: ...thin the control panel software to become proficient in routing and mixing If somewhere in the process you become confused you may always restore the default settings to use the card as a straight 2 i...

Страница 13: ...is disabled greyed out when the master clock is set to internal crystal When S PDIF In is used as the master clock the software applications need to be manually informed of the S PDIF Input sample rat...

Страница 14: ...d checkbox will allow you to force the settings of a few particular status bits in the outgoing digital audio stream The advanced option is for expert users only otherwise select Restore Defaults to a...

Страница 15: ...AVE DELETE LOAD The Delta Control Panel will retain the last settings that were entered except for mixer channels with solo settings they will default back to on and not to solo or muted However the S...

Страница 16: ...r computer off before making the connections In this example we will connect a DAT to the Delta DiO card using coaxial S PDIF cables typically 75 ohm We ll also connect the DiO s analog outputs to a s...

Страница 17: ...recording from an S PDIF input you will need to setup the DiO board to synchronize its master clock with the S PDIF input To do this open the Hardware Settings page of the control panel software Unde...

Страница 18: ...gital audio is making it into the DiO correctly Transferring from DiO to DAT monitoring with DAT 1 Connect the DiO coaxial S PDIF Output to the DAT coaxial S PDIF Input using a good quality digital ca...

Страница 19: ...e outputs of your music software will be sent to the DiO S PDIF Out and consequently to the DAT 5 Next let s make sure the S PDIF output format is correct Open the S PDIF page of the control panel sof...

Страница 20: ...ossible that there is a resource problem that is not showing up in the conflicting resource list or as a yellow exclamation point in the Device Manager If you have any doubt about the configuration of...

Страница 21: ...sets of hardware profiles See your Windows documentation for help in this area NOTE When resolving conflicts between PnP and non PnP devices it is usually easier to re adjust the resource settings of...

Страница 22: ...e 1 Wrong S PDIF input coaxial or optical is selected in the Delta Control Panel software Possible Cause 2 The Delta DiO input s are not properly selected in the user s application software Possible C...

Страница 23: ...f system bandwidth preventing the recording buffer of an audio card from keeping up with demand This can cause clicks in the recording This problem may often be solved by reducing or turning off the g...

Страница 24: ...customer will have the option to pay this fee and have the unit repaired and returned or not pay this fee and have the unit returned unre paired The remedy for breach of this limited warranty shall no...