6. Maintenance 

 

The motor does not need any maintenance. Opening or disassembling of the motor 

would cause a forfeit of warranty claims! It could be also very dangerous, due to very 
strong magnets on rotor! 

 

Though, it must be considered that no foreign objects at all can enter the interior of 

the drive. 

Further, it is necessary to protect the motor from humidity, dirt, paint, glues etc. If 

this is ignored, a proper functionality of the motor cannot be guaranteed, and irreparable 
damages are possible. In case of damage, ship the drive back to the manufacturer for 

repairs. Unintended handling leads to secondary damages. 

Keep magnetic memory cards or electronic devices out of the rotor’s close

-up range, 

because the alternating magnetic field can cause a delete of data. Be also careful with 
medical devices (e.g. pacemakers) which are sensitive to alternating magnetic fields. 

 
The small gap between the stator and the magnets of the rotor function-bound has a 

thickness of only a few tenth millimeters. Here, the danger of foreign objects accumulating 

in this gap exists but can be heard by scratching-sounds. In this case spinner should be 
removed and the motor should be blown-out with compressed air. Do not at all simply 
keep on using the drive. Be especially aware of cuttings which can almost irremovably 
stick to the magnets. In this case, the only thing that helps is a disassembly of the drive 

by the manufacturer. 

 

Содержание FES-VEN-M100

Страница 1: ...FES MOTOR MANUAL Version 1 1 Type FES VEN M100 LZ design d o o Brod 3D 1370 Logatec Slovenia tel 386 59 948 898 info lzdesign si front electric sustainer com...

Страница 2: ...of Content 1 Important notices 3 1 1 Limited Warranty 3 2 General 4 3 Model designation 4 4 Technical data and limitations of motor 5 5 Drawing of motor 7 6 Maintenance 8 7 Removal of motor 9 8 Insta...

Страница 3: ...ion repair or replace any components that fail in normal use Such repairs or replacement will be made at no charge to the customer for parts and labor the customer shall be responsible for any transpo...

Страница 4: ...drive without the usually essential gear unit which cause power losses additional weight complexity and maintenances Because of the little internal resistance of the motor very good performances are a...

Страница 5: ...llers Electrical motor type FES VEN M100 power ratings at 116V on motor controller and loaded with FES VEN P1 102 propeller Maximum torque 75 Nm Maximum current 200A Maximum Voltage 180V Rpm non loade...

Страница 6: ...VEN M100 MOTOR manual Version 1 1 June 2020 Page 6 of 10 Power Consumption 0 0 Horizontal flight Max climb 0 5 10 15 20 25 0 1000 2000 3000 4000 5000 n RPM P kw Power consumption curve Rpm versus Pow...

Страница 7: ...FES VEN M100 MOTOR manual Version 1 1 June 2020 Page 7 of 10 5 Drawing of motor...

Страница 8: ...ed handling leads to secondary damages Keep magnetic memory cards or electronic devices out of the rotor s close up range because the alternating magnetic field can cause a delete of data Be also care...

Страница 9: ...which is below powers wires have lower head Hold motor assembly and carefully take it out of fuselage 8 Installation of motor To install motor back on glider follow the reverse order Take care about a...

Страница 10: ...1 1 June 2020 Page 10 of 10 9 Repair and service In case of a fault or damage please contact manufacturer 10 Revision history July 2015 Initial release of manual Version 1 0 June 2020 Minor updates u...

Отзывы: