6. Maintenance 

 

The motor does not need any maintenance. Opening or disassembling of 

the motor would cause a forfeit of warranty claims! It could be also very 
dangerous, due to very strong magnets on rotor! 

 

Though, it has to be considered that no foreign objects at all can enter the interior of 

the drive. 

Further, it is necessary to protect the motor from humidity, dirt, paint, glues etc. If 

this is ignored, a proper functionality of the motor cannot be guaranteed, and irreparable 
damages are possible. In case of damage, ship the drive back to the manufacturer for 
repairs. Unintended handling leads to secondary damages. 

Keep magnetic memory cards or electronic devices out of the rotor’s close

-up range, 

because the alternating magnetic field can cause a delete of data. Be also careful with 
medical devices (e.g. pacemakers) which are sensitive to alternating magnetic fields. 

 

The small gap between the stator and the magnets of the rotor function-bound has a 

thickness of only a few tenth of millimeter. Here, the danger of foreign objects 
accumulating in this gap exists but can be heard by scratching-sounds. In this case 

spinner should be removed and the motor should be blown-out with compressed air. Do 
not at all simply keep on using the drive. Be especially aware of cuttings which can almost 
irremovably stick to the magnets. In this case, the only thing that helps is a disassembly 
of the drive by the manufacturer. 

 

 

 

Содержание FES-LS8-M100

Страница 1: ...FES MOTOR MANUAL Version 1 21 Type FES LS8 M100 LZ design d o o Brod 3D 1370 Logatec Slovenia tel 386 59 948 898 info lzdesign si front electric sustainer com...

Страница 2: ...e of Content 1 Important notices 3 1 1 Limited Warranty 3 2 General 4 3 Model designation 4 4 Technical data and limitations of motor 5 5 Drawing of motor 7 6 Maintenance 8 7 Removal of motor 9 8 Inst...

Страница 3: ...not cover failures due to abuse misuse accident or unauthorized alterations or repairs THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPL...

Страница 4: ...arless drive without the usually essential gear unit which cause power losses additional weight complexity and maintenances Because of the little internal resistance of the motor very good performance...

Страница 5: ...ollers Electrical motor type FES LS8 M100 power ratings at 116V on motor controller and loaded with FES LS8 P1 102 propeller Maximum torque 75 Nm Maximum current 200A Maximum Voltage 116V Rpm non load...

Страница 6: ...LS8 M100 MOTOR manual Version 1 21 April 2020 Page 6 of 12 Power Consumption 0 0 Horizontal flight Max climb 0 5 10 15 20 25 0 1000 2000 3000 4000 5000 n RPM P kw Power consumption curve Rpm versus Po...

Страница 7: ...FES LS8 M100 MOTOR manual Version 1 21 April 2020 Page 7 of 12 5 Drawing of motor...

Страница 8: ...ded handling leads to secondary damages Keep magnetic memory cards or electronic devices out of the rotor s close up range because the alternating magnetic field can cause a delete of data Be also car...

Страница 9: ...mounting wall are visible four M8 nuts tightened over big spacer and rubber silen blocks Please leave them at they are Proper way of removing motor is to follow next steps To remove the motor assembly...

Страница 10: ...h different colour of isolation over the cable shoe red blue and black Take a photo so that you will know their proper order for assembly 5 Un secure six M8 bolts and unscrew them note that M8 screw l...

Страница 11: ...ides with spring locks After motor is reinstalled check that Spinner is nicely located in the middle of the fuselage when spinner is in stop position This means that surface of the spinner is as much...

Страница 12: ...R manual Version 1 21 April 2020 Page 12 of 12 9 Repair and service In case of a fault or damage please contact manufacturer 10 Revision history April 2019 Initial release of manual v1 2 April 2020 Mi...

Отзывы: