5
Button
„minus”
Decreasing the time on the timer, after
which the pump will be stopped
automatically. The indication 00:00:00
will deactivate the function of automatic
pump operating time stoppage. Setting
may be changed in the start mode.
Button
„i”
Displaying the help – active in the stop
status.
Button
„…”
Changing the operating mode <->
creaming/pumping. Button active in
stop status.
Button
„STOP”
Stopping the pumping.
Button
„START” Pumping activation.
2.3. CONTROLLER DIAGNOSTICS
FM-02 controller has been equipped with
advanced diagnostics procedures – allowing to make
tests. In order to enter the diagnostic mode, Press
button no 5 during the proper chase of the controller
start-up (see picture below)
Fig 5.
Controller view during start-up
Button numbers
Diagnostic screen is divided into 14 sections, their
functions, see below. Leaving the diagnostic screen,
diagnostic goes automatically after 25 s.
Fig 6.
Screen
–
controller diagnostic.
Secti
on
descripti
o n
Indication
Funkcja
1
CPU
1E9705
Displaying the
value other than
1E9705
Indicates the
Damages of the
main processor.
2
EEPROM OK /
ERROR
f ERROR notice m
Multiple, repetitive
(despite controller
restarting)
appearance o the
damages of EEprom
memory
cell/cells in the
controller
3
Vcpu [V] 4,60 – 5,40
Measurement of
the power supply
voltage for the
CPU module of the
controller.
Indication outside
the range means
damage/
overloading
of the feeder or
CPU module
damage.
1
2
3
4
5
6
7
8