Lyon LMK6-ST Скачать руководство пользователя страница 21

5

Warning: the safe working life of this 

product may be as short as its first use 

in extreme circumstances.

If in doubt, do not hesitate to scrap this 
product.

Guarantee

In the event of any defect in materials 
or workmanship please return the 
product to the dealer, distributor or 
manufacturer within 3 years of purchase 
for inspection. We will replace or 
repair as required. This guarantee does 
not cover normal wear and tear or 
accidental damage.

Note to resellers

If the product is re-sold outside the 
UK and Eire, but within the EU, the 
reseller is responsible for providing 
instructions for use, maintenance, 
periodic examination and for repair in 
the language of the country in which the 
product is to be used. 

If you require the Intrastat commodity 
code / customs tariff code or NATO 
stock number (where applicable) for 
this product, please contact us via 

lyon.co.uk

Inspection records

A record must be kept for each 
component, subsystem and system, 
including name and contact details of 
the manufacturer or supplier, product 
description, serial number, year of 
manufacture, date of purchase, date of 

first use, any other relevant information, 

and history of periodic examinations 
and repairs, the name and signature of 

the competent inspector and the next 
due date for inspection. An example of 
a suitable equipment record is shown 
on this user instruction and can also be 
downloaded at lyon.co.uk

Local jurisdiction may dictate that 
extra information be recorded in 
the inspection record – check your 
country’s legal requirements. Some 
products may have features which need 
special monitoring during periodic 
inspections, e.g. wear indicators, in 
which case this information should also 
be recorded on the inspection record.

UI_GENSCA6_19052.indd   5

06/03/2019   13:04:18

Downloaded from lyon.co.uk

Содержание LMK6-ST

Страница 1: ...above or scan the QR code with your smart phone USER INSTRUCTIONS Lyon Equipment Limited Units 3 7 Tebay Business Park Old Tebay Penrith Cumbria United Kingdom CA10 3SS Tel 44 0 15396 24040 Email info...

Страница 2: ...CE 93 42 EEC Class 1 2007 47 EC Nomenclature of parts Stretcher 1 Top tube 2 Skid 3 Bed 4 Strengthening plate 5 Damper sleeve 6 Foam pad 7 Handle 8 Joint locking toggle bolt 9 Joint locking pin 10 Hea...

Страница 3: ...3 Stretcher 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 UI_LMK6 ST_16347 indd 3 18 04 2019 10 57 40 Downloaded from lyon co uk...

Страница 4: ...4 Pack Frame accessory 18 19 20 21 22 Wheel unit accessory 30 32 31 Headguard accessory 25 24 23 UI_LMK6 ST_16347 indd 4 18 04 2019 10 57 40 Downloaded from lyon co uk...

Страница 5: ...tion with compatible items of personal fall protection equipment of suitable specification with due consideration to the limitations of each individual piece of equipment in the safety chain A minimum...

Страница 6: ...ONLY BE TIGHTENED BY HAND DO NOT USETOOLS Insert the two joint locking pins into the top tubes Ensure they are fully inserted and the spring bail closed over the tube Place the stretcher on the ground...

Страница 7: ...re to ensure the casualty is not further injured by poor fitting trapping parts of the body adjustment of straps or by displacement of straps during the rescue Do not allow the stretcher or any compon...

Страница 8: ...by slackening the webbing through the adjuster and then pushing both brass levers simultaneously towards the adjuster The buckle will then release Disassembly of the stretcher Lower and secure the he...

Страница 9: ...e stretcher section to prevent accidental contact Carrying the loaded stretcher Be aware that a loaded stretcher stretcher casualty medical equipment may weigh up to 136 kg Multiple personnel are requ...

Страница 10: ...e when tensioning the rope between them A second Alpine butterfly knot is now tied in the rope and connected into the opposite head end suspension point via a suitable connector The knot position and...

Страница 11: ...n The stretcher should be subject to Pre use checks Thorough inspections Interim inspections as appropriate The stretcher and all components should be checked Loosen all straps and move adjusters conn...

Страница 12: ...visual inspection for any signs of corrosion permanent deformation or other damage There should be no broken strands or kinks in the wire The ferrules should be tight with no movement of wire within t...

Страница 13: ...keep metal items at temperatures between 20 C and 60 C Always keep textile items at temperatures between 30 C and 50 C Maintaining your equipment See General User Instructions for information on clea...

Страница 14: ...give the year of manufacture the next three digits the day of the year from 001 to 365 and the five digits after is the number in the series Maximum rated load carry via handles Maximum rated load hor...

Страница 15: ...15 This page deliberately left blank UI_LMK6 ST_16347 indd 15 18 04 2019 10 57 41 Downloaded from lyon co uk...

Страница 16: ...ddress Other relevant information Record of inspection and repair Date Next due date Name and signature of competent inspector Comments Tel 44 0 15396 24040 Fax 44 0 15396 26330 info lyon co uk lyon c...

Страница 17: ...the link above or scan the QR code with your smart phone General user instructions Lyon Equipment Limited Units 3 7 Tebay Business Park Old Tebay Penrith Cumbria United Kingdom CA10 3SS Tel 44 0 15396...

Страница 18: ...in these instructions are examples only many other misuses may exist which could lead to injury or death Do not use combinations of items of equipment in which the safe function of any one item is af...

Страница 19: ...dge protection if necessary On each occasion of use verify the free space required beneath the user in order to avoid an impact Always try to place protection so that any fall will be stopped before t...

Страница 20: ...nuing correct performance of this product PPE Personal Protective Equipment inspection training is available from Lyon Equipment Lifetime and when to withdraw your equipment from use Withdraw your equ...

Страница 21: ...mber where applicable for this product please contact us via lyon co uk Inspection records A record must be kept for each component subsystem and system including name and contact details of the manuf...

Страница 22: ...6 This page deliberately left blank UI_GENSCA6_19052 indd 6 06 03 2019 13 04 18 Downloaded from lyon co uk...

Страница 23: ...on of symbols Refer to user instructions Permitted use Caution Danger of death Telephone number Anchor point Rope diameter Cable SWL Safe Working Load UI_GENSCA6_19052 indd 7 06 03 2019 13 04 18 Downl...

Страница 24: ...dress Other relevant information Record of inspection and repair Date Next due date Name and signature of competent inspector Comments Tel 44 0 15396 24040 Fax 44 0 15396 26330 info lyon co uk lyon co...

Отзывы: