background image

Contact us direct for fast friendly service (800) 477-1255

9117-CA

1/4"-20 X 1"

SLOTTED HEAD SCREW

1/4"-20 HEX NUT

#8-32 x 3/8"

FLAT HEAD TAPPING SCREW

1.)  BEFORE INSTALLING MODULAR DRAWER UNITS, IT MUST BE

VERIFIED THAT THE UPRIGHTS ARE PLUMB AND THE SHELVES
ARE LEVEL.  THE SHELVING UNIT MUST ALSO BE PROPERLY
ANCHORED AS DESCRIBED IN THE INSTALLATION SHEET

PROVIDED WITH THE SHELVING UNIT.  IF NEEDED, CONTACT
REPUBLIC CUSTOMER SERVICE FOR PROPER ANCHORING
METHODS.  DRAWERS WILL NOT OPERATE CORRECTLY IF THE

ABOVE CRITERIA IS NOT MET.

2.)  EACH UNIT MUST HAVE A SHELF ABOVE AND BELOW THE UNIT.

TWO UNITS IN ONE SHELVING SECTION MUST BE SEPARATED BY
A SHELF.  THE SHELF SPACING FOR EACH UNIT IS 1 1/2"
GREATER THAN NOMINAL.  EXAMPLE: ONE 24" UNIT (30
SEGMENTS) REQUIRES A SPACE OF 25 1/2".  THIS SPACE IS

MEASURED FROM TOP OF SHELF TO TOP OF SHELF.

3.)  MODULAR DRAWERS ARE AVAILABLE IN THE FOLLOWING SIZES:

ANY COMBINATION OF DRAWER SEGMENTS TOTALING 15 FOR
THE 12" UNIT, 22 FOR THE 18" UNIT, 30 FOR THE 24" UNIT OR 45

FOR THE 36" UNIT MAY BE USED

REAR BRACKETS

(2 PIECES)

FRONT BRACKETS

(2 PIECES)

HORIZONTAL TRIM

(1 PIECE)

(4 PIECES)

(4 PIECES)

(2 PIECES PER DRAWER)

SHEET 1

PANEL CLIP

(2 PIECES)

LH

RH

LH

RH

Содержание 2000 Series

Страница 1: ... CORRECTLY IF THE ABOVE CRITERIA IS NOT MET 2 EACH UNIT MUST HAVE A SHELF ABOVE AND BELOW THE UNIT TWO UNITS IN ONE SHELVING SECTION MUST BE SEPARATED BY A SHELF THE SHELF SPACING FOR EACH UNIT IS 1 1 2 GREATER THAN NOMINAL EXAMPLE ONE 24 UNIT 30 SEGMENTS REQUIRES A SPACE OF 25 1 2 THIS SPACE IS MEASURED FROM TOP OF SHELF TO TOP OF SHELF 3 MODULAR DRAWERS ARE AVAILABLE IN THE FOLLOWING SIZES ANY C...

Страница 2: ...EASURED FROM TOP OF SHELF TO TOP OF SHELF 2 ATTACH THE FRONT AND REAR BRACKETS BY ALIGNING THE TANGS TO THE SQUARE HOLES IN THE POSTS AND PRESSING DOWN SECURE BRACKETS IN PLACE WITH 1 1 4 20x1 BOLT AND NUT AT THE BOTTOM OF EACH BRACKET WHEN ASSEMBLING A ROW OF SHELVING WITH MATCHING MODULAR DRAWER UNITS THE SAME BOLT CAN BE USED TO ATTACH ADJACENT MOUNTING BRACKETS TO AN INTERMEDIATE SHELVING UPRI...

Страница 3: ...PAY ATTENTION TO RIGHT HAND AND LEFT HAND WHEN ASSEMBLING AFTER THE MIDDLE SECTIONS OF THE SLIDES ARE INSERTED MAKE SURE THE SAFETY CATCHES ARE UNLOCKED BEFORE ATTEMPTING TO INSERT A DRAWER 8 32 x 3 8 FLAT HEAD TAPPING SCREW 2 PER DRAWER SUPPLIED WITH DRAWER LH RH MARKING RH SHOWN FRONT OF SLIDE FRONT OF SLIDE DETAIL SHOWING SAFETY CATCH UNLOCKED STATIONARY SECTION OF SLIDE MIDDLE SECTION OF SLIDE...

Страница 4: ... SLIPPING OVER THE DRAWER STOPS 2 CONTINUE TO INSTALL DRAWER SLIDES FOR THE REMAINING DRAWERS THE SPACING IS DETERMINED BY THE HEIGHT OF THE DRAWER FRONT BELOW THE NEXT DRAWER SLIDE SHOULD BE JUST ABOVE THE DRAWER FRONT BELOW REFER TO ASSEMBLY OPERATION 2 FOR MORE DETAILED INSTRUCTIONS ON DRAWER SLIDE INSTALLATION 8 32 x 3 8 FLAT HEAD TAPPING SCREW 2 PER DRAWER SUPPLIED WITH DRAWER Contact us dire...

Страница 5: ...ANY OTHER DESIRED SHELVES AT THIS TIME 2 ATTACH HORIZONTAL TRIM PIECE TO FACE OF SHELF WITH 2 PANEL CLIPS IF DRAWER PARTITIONS AND DIVIDERS WERE ORDERED THEY CAN BE INSTALLED AT THIS TIME PANEL CLIP 2 PIECES Contact us direct for fast friendly service 800 477 1255 9117 CA ...