Power Lead Strain Relief
The module has a small hole in the case located above the power
connection to prevent the power lead being accidentally pulled out.
Use the supplied tie-wrap and secure the lead as shown below.
Connections
The SDI video outputs are connected to the corresponding 75 Ohm
BNC connections provided. The fiber connection is made to the fiber
SFP sub module as indicated on the module.
Four versions of the module are available, the only difference is the SFP
sub module installed into the basic module.
ORX 1802 LC
- Singlemode LC fiber connection
ORX 1802 ST
- Singlemode ST fiber connection
ORX 1802 SC
- Singlemode SC fiber connection
ORX 1802 MM
- Multimode LC fiber connection
The module fiber connection is supplied with a rubber plug installed,
this is to prevent dust contamination. Please retain the plug and use if
the cable is ever disconnected from the module.
Operation
Operation of the ORX 1802 is fully automatic. The SDI video format is
automatically detected, reclocked and provided on two SDI output
connections. The module supports all SDI video standards as well as
DVB/ASI.
The ORX 1802 supports hot swapping and hot plugging of
connections.
No user settings are provided for this module.
Power
The module requires a 12V DC power input and a LED is provided to
confirm power is connected. A power supply is provided, but if
applying your own power, please provide a clean 12V DC power
source. Module power consumption is approx 1.4W
SFP Fiber sub modules plug into the basic base
module
LC
Singlemode
ST
Singlemode
SC
Singlemode
LC
Multimode
g
ORX 1802 MM
- Multimode LC fiber connection
LC
Singlemode
ST
Singlemode
SC
Singlemode
LC
Multimode