Lynx yellobrik OTT 1842-1 Скачать руководство пользователя страница 2

Connections

The SDI video input is connected to the 75 Ohm BNC connections (up 

to 3Gbit). The fiber connection is LC Duplex SMF (Singlemode).  An 

example of the LC connector shown below (fiber Optic cable and LC 

connectors are not supplied)

Operation

The module supports CWDM and has two independent channels,  each 

with a different wavelength (selected at time of order,  installed 

wavelengths are indicated with a white label on top of the module). 

Operation is fully automatic. The SDI Input video rates are automatically 

detected, reclocked and transmitted over the optical connections.

The OTT 1842-1 supports any SDI video signal from 270Mbit/s to 

3Gbit/s.  Maximum distance is 40 km (24.8 miles).  Data transmission 

activity is indicated by the TX LEDs on the side of the module.  

Note.

 

If TX LED is OFF this indicates no SDI input is present, or not a 

valid input.

The module supports hot swapping and hot plugging of connections.

No user settings are provided for this module.

 

Power

The module requires a 12V DC power input and a LED is provided to 

confirm power is connected.  A power supply is provided, but if 

applying your own power, please provide a clean 12V DC power source. 

Module power consumption is approx 250mA (2.8VA)

Power Lead Strain Relief

The module has a small hole in the case located above the power 

connection to prevent the power lead being accidentally pulled out. 

Use the supplied tie-wrap and secure the lead as shown below.

*

Note

The module is a CWDM device and can only be 

used with SMF (Singlemode fiber). Multimode 

fiber is not supported.

Optional Mounting Bracket

The optional RFR 1001 mounting bracket  can be used to permanently 

mount the module on any flat surface or on 19” rack rails.  