![Lynx PTG 1802 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/lynx/ptg-1802/ptg-1802_user-manual_1954023011.webp)
10
Cage / Markers Overlay
Blanking edge/safe action/safe title boxes can be superimposed onto
each SDI output. The positions of the boxes are at 90% (safe action) and
80% (safe title), as specified in SMPTE RP218-2002.
The following selections are available:
• OFF [
Default
]
•
Blanking Edge
•
SMPTE safe action (90/90) according to SMPTE RP218-2002
•
SMPTE safe title (80/80) according to SMPTE RP218-2002
Navigation:
HOME > PATTERN >SDI (X) > OVERLAY > CAGE >
(select)
Setting Audio
Audio Generators
Two audio generators are provided, each generator has four channels and
each channel can be configured independently. The following selections
are available
•
Frequencies: 50Hz, 100Hz, 200Hz, 250Hz, 400Hz, 500Hz, 800Hz,
1kHz, 2kHz 3kHz, 4kHz, 8kHz, 16kHz [
Default 1kHz
]
• Adj. Amplitude: 0dBFS to -79dBFS in 1dB steps [
Default -18dBFS
]
• IDENT – [ON or OFF] typically used to put a small
repeating break (or pause) in the audio signal to easily identify a
specific channel [
Default OFF
]
• BREAK [ON or OFF]. Switch the selected channel ON (silent) or OFF
[
Default OFF
]
To configure Audio Generator A
Navigation:
HOME > AUDIO > GEN A
To configure Audio Generator B
Navigation:
HOME > AUDIO > GEN B