DIP Switch 1
enables local adjustments. Setting it to ON enables the setting of the other
DIP switches to configure the module. Setting it to OFF will prevent any
local DIP switch settings from taking effect.
NOTE: It is recommended to set DIP switch #1 to OFF to prevent from accidental
changes to the stored module configuration if the switches are moved.
DIP Switch 2
configures the audio embedder for embedded Group 1. Setting it to ON
enables the embedder: Group 1 will be embedded, replacing the previous
content of Group 1 (if any). Setting it to OFF disables the embedder for
Group 1.
DIP switch 3
configures the audio embedder for embedded Group 2. Setting it to ON
enables the embedder: Group 2 will be embedded, replacing the previous
content of Group 2, if any. Setting it to OFF disables the embedder for
Group 2.
DIP switch 4
configures the audio embedder for embedded Group 3. Setting it to ON
enables the embedder: Group 3 will be embedded, replacing the previous
content of Group 3, if any. Setting it to OFF disables the embedder for
Group 3.
DIP switch 5
configures the audio embedder for embedded Group 4. Setting it to ON
enables the embedder: Group 4 will be embedded, replacing the previous
content of Group 4, if any. Setting it to OFF disables the embedder for
Group 4.
DIP Switch 6
enables blanking of the complete horizontal blanking interval (all HANC
data will be removed from SDI). Note that Audio Embedding (Group 1-4)
also modifies the HANC space by adding / replacing data.
DIP Switch 7
enables blanking of the complete vertical blanking interval (all VANC data
will be removed from SDI).
Factory Preset Condition
The P DM 5240 is delivered programmed and preset for the following mode of operation:
Switch 1
ON
Local Adjustment Enabled
Switch 2
ON
Embedders for Group 1 enabled
Switch 3
ON
Embedders for Group 2 enabled
Switch 4
ON
Embedders for Group 3 enabled
Switch 5
ON
Embedders for Group 4 enabled
Switch 6
OFF
HANC data passes unmodified (except Audio Groups)
Switch 7
OFF
VANC data passes unmodified
Auto Store
The current settings are stored to the local Flash RAM 10 seconds after the last
modification. As a confirmation, the Alarm LED flashes three times, see below. See
section “Save Settings Now” on page 28 for more details.
Reset Button
If this button is pressed for 5 seconds, all internal parameters will be reset to their factory
default values. To confirm this reset, the device will blink all LEDs once (OFF – ON –
OFF) and then return to their normal state.