Download the LynxCentraal Control GUI from www.lynx-technik.com, to setup and 
configure a LYNX system from a PC. The LynxCentraal GUI can be disconnected 
after  the  system  has  been  configured  (because  all  settings  of  all  devices  are 
automatically stored in the module

’s flash RAM). Alternatively, the 

LynxCentraal 

GUI can stay connected permanently for monitoring and real time status updates 
from the system.

 

 

Install LynxCentraal on a PC in the same network as your devices. 

 

Start the application

.

 

 

Login  as 

Main  Admin

  with  the  default  password 

1main$admin 

(the  Main 

Admin password is NOT editable!) 

 

 

Select the Operator Feature Page

 (item 1).

 

 

Migrate existing users and designs

 (click item 2)

. It is best to do this first, 

rather than waiting until new operators have been added. The migrate function 
lists all operators and designs it finds in the network, and you have a choice 
which ones you would like to keep. 

How?

 

Confirm your selection with 

Migrate

 

(item 3).

 

 

Add new Operators and Administrators - press 

Add Operator

 (item 4)

 and set 

a name, initial password and operator type

.

 

 

For each newly added operator, 

use drag & drop to 

select features, designs 

and servers 

(items 5) 

which are permitted to him or her.

 

 

Содержание LynxCentraal 5000 Series

Страница 1: ...ntraal Broadcast Television Equipment 5000 Series Quick Start Guide 2022 LYNXTechnik AG Page 1 LynxCentraal 5000 Series Quick Start Guide Revision 1 0 RELEASE Last Updated May 2022 Service Contact sup...

Страница 2: ...patterns for greenMachine Testor custom control panels and other data between all workstations in the LYNX universe Since there was no such redundancy and advanced user management in the 5000 series i...

Страница 3: ...ckly change settings in your environment LynxCentraal contains an enhanced redundancy management engine for synchronizing operator account information custom patterns for greenMachine Testor custom co...

Страница 4: ...on a PC in the same network as your devices Start the application Login as Main Admin with the default password 1main admin the Main Admin password is NOT editable Select the Operator Feature Page it...

Страница 5: ...wn or hot keys There is a dedicated page for each of the hardware device types Series 5000 blue greenMachine green and yellobrik yellow Functions which all devices share are available as additional pa...

Страница 6: ...her via an IP network The RCT 5023 G is the basic controller card and is all you need to connect a Series 5000 2RU rack frame to the LynxCentraal Control software The controller card has a LAN network...

Страница 7: ...individual IP address The entire system is accessible under two different IP addresses NOTE The processing boards will continue to work even if the Primary SERVER is not available In the event of a se...

Страница 8: ...for the current operator or servers which were filtered out by the current operator do not show up in this table Available Rack Controllers The available rack controllers table on the right lists all...

Страница 9: ...to three control servers Each server can assign an individual name to the controller Options of Detaching a RCT 5023 Rack Controller from a Control SERVER 1 Select the RCT 5023 or RCT 1012 rack contro...

Страница 10: ...e LYNX RackController or LYNX Server in the list and do one of the following 1 If the system is connected to a network and you have a DHCP server Activate the DHCP checkbox so that the LYNX Controller...

Страница 11: ...default factory setting admin password is lynx admin Repeat the above steps 1 or 2 for all LYNX RackControllers and LYNX Servers which need to be connected to your network NOTE If your LYNX component...

Страница 12: ...input is removed the GUI will update the appropriate status information immediately usually within 500 msec NOTE Any changes to the configuration of a card by mouse click in the GUI are communicated d...

Отзывы: