background image

Reference Manual C AD 5131 Version1.1

 

Page 4   

Regulatory information 

Europe 

Declaration of Conformity 
 
 
 
 
 
 
 
 
 
 
 

 
 

USA 

FCC 47 Part 15

 

  

This device complies with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause 
undesired operation. 

   

Note: This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to the part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own 
expense

 

We

  

 

LYNX Technik AG 

    

Brunnenweg 

    

D-64331 

Weiterstadt 

    

Germany 

 

Declare under our sole responsibility that the product

 

  
 

 

TYPE: C AD 5131  

 

  

To which this declaration relates is in conformity with the following 
standards: 
 

 

EN 55103-1   /1996 

 

EN 55103-2   /1996 

  

EN 60950   /1997 

 

Following the provisions of 89/336/EEC and 73/23/EEC directives.

 

      

 

 

         

Winfried Deckelmann 

   
 
Weiterstadt, June 2003 

 
  Place and date of issue                          Legal Signature

 

 

 

 

                   

 

 

Содержание CardModule C AD 5131

Страница 1: ...ik com Reference Manual C AD 5131 Analog Video to SDI Conv Line Synchronizer CardModule Analog Video to SDI Conv C AD 5131 Analog Video to SDI Conv Line Synch C AD 5131 REF in REF loop Y 1 in Y 2 in U C 1 in U C2 in V 1 in V 2 in SDI out 1 SDI out 2 LYNX Technik AG 5 1 3 1 Version 1 1 ...

Страница 2: ... written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except as expressly written by LYNX Technik AG the furnishing of this document does not give you any license to patents trademarks copyrights or other intellectual property of LYNX Technik AG or any of i...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install repair or service the product b to repair damage resulting from improper use or connection to...

Страница 4: ...e equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfe...

Страница 5: ...ule Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Multi Function Switch 13 Using the Local Display Menus 14 Navigation 14 Local Adjustments Available 14 Menu Structure 15 Factory Preset Condition 20 Auto Store 20 Alarm LED Status Indicators 21 Status Indicators 21 Alarm Indicator 21 Locate Function 22 Specifications C AD 5131 23 Available Options 24 Parts Lis...

Страница 6: ...Reference Manual C AD 5131 Version1 1 Page 6 This page is intentionally left blank ...

Страница 7: ...put signals can be selected The input Architecture is differential to assure optimal resistance against distortion 525 625 Input detection is automatic Either an external loop through reference or the internal rack reference black burst signal can be used to line synchronize the two SDI outputs The C AD 5131 features a wide range of available adjustments via optional Rack Controller basic adjustme...

Страница 8: ...ows the physical layout of the C AD 5131 CardModule and also the connection panel which is fitted to the rear of the rack Multi Function Switch MUX Genlock A D Conversion Decoder S Video Selectable Chroma Luma Filter Line Synchronizer SDI out 1 SDI out 2 PAR SER Micro Controller Alarm Staus LEDs UP DN ENTER Ref IN REF Loop Y 1 in Control Rack Reference Test Signal U C 1 in V 1 in Y 2 in U C 2 in V...

Страница 9: ... Panel PCB Front View LED 1 LED 2 LED 3 Alarm UP DN Press for ENTER 5111 LED 4 CVBS to SDI Conv Matrix Display Analog Video to SDI Conv Line Synch C AD 5131 REF in REF loop Y 1 in Y 2 in U C 1 in U C2 in V 1 in V 2 in SDI out 1 SDI out 2 LYNX Technik AG Analog Video to SDI Conv C AD 5131 5 1 3 1 ...

Страница 10: ...ard 75 Ohm BNC connectors Connection is self explanatory We recommend the use of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 820 feet Belden 8281 270Mbits s Note Due to the compact design of the connection plate it will be necessary to use a connectio...

Страница 11: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module into the card frame and carefully check the CardModule easily connects to the rear connection plate The card should fit easily and should not require excessive force to insert if you feel any resistan...

Страница 12: ...nction switch and 4 character dot matrix display or from remote when using one of the optional controllers and control software Once set all settings are automatically saved in non volatile internal memory Flash ram The module will always recall the settings used prior to power down Figure 3 Switch and Display Location Analog Video to SDI Conv C AD 5131 Multifunction Switch Matrix Display 5 1 3 1 ...

Страница 13: ...Page 13 Multi Function Switch The CardModule is equipped with a multi function switch located on the front bottom edge of the card refer to figure 3 Figure 4 Switch Operation Up Down Enter Switch Operations Multi function Switch Side Front ...

Страница 14: ... Available All of the critical adjustments to the module are accessible using the local display and multi function switch these include Input Signal A B select Input YCrCb YC mode select External Rack Internal line sync reference select Analog input filter on off Genlock mode Luma chroma filter settings Auto manual gain control Test signal select A set of extended adjustments is possible when usin...

Страница 15: ... Notes Tips ENTER moves between Levels UP DOWN moves between items within the level When you enter a new setting the system will jump back one level in the menu system The back selection in the menu structure will take you back one level when selected When an item is selected which has several setting possibilities the first value displayed will be the value currently stored in the system The orde...

Страница 16: ...r selection Video standard selection a c k b N I 1 G S N A I N B I a c k b 1 L T F 1 3 1 5 F F O L A T F N H E a c k b T D S 2 5 5 U T O A 2 5 6 a c k b O M P C C Y a c k b Mode Select COMP Y Pr Pb Component Analog YC Y C seperated S Video O D E M NOTE For automatic mode if input video and the reference signal are different standards then the reference input will be ignored ...

Страница 17: ...0 1715 for 525 0 1727 for 625 automatic wrap to next lne when limit reached Select luminance filter 1 18 default 18 O Q L Q M a c k b S N C L X T E N T I F F O a c k b L A Y D I N E L I X L P a c k b a c k b 0 0 0 0 0 0 0 0 E N L G I D V I L T F U M L 0 0 0 0 I Q H LO Q Video Tracking Mode for inputs with poor signal quality No line synch function M Q For poor input signal quality with timebase an...

Страница 18: ...7 M 0 3 M 1 5 M 1 8 M 1 2 M 2 a c k b Set luminance gain AUTO based on sync tip amplitude MAN Enter required gain value Set Chroma gain AUTO based on Luma gain MAN Enter required gain value A I N G U T O A A N M a c k b U T O A A N M a c k b a c k b 0 0 0 0 0 0 0 0 a c k b U M L 0 L C 0 M 3 ...

Страница 19: ...al BAR Color Bars BLK Black EQ Equaliser pathological test signal PLL PLL pathological test signal Select test signal standard Restore factory defaults T D S a c k b a c k b 2 5 6 2 5 5 A R B L K B Q E L L P F F O a c k b O N E S Y a c k b E S T T S E T R L C T S ...

Страница 20: ...ay 0000 Pixel delay 0000 Lum filter 18 Chroma filter 3 0M Lum gain Auto Chroma gain Auto Test Signal Bars If this is the mode of operation required then no adjustments are necessary These settings can be recalled at any time by selecting reset from the menu system Auto Store If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically this c...

Страница 21: ...igure 2 Alarm Indicator There is also a single alarm LED on the lower edge of the module LED 3 This is visible through the card frame front cover and provides a general indication of the module status LED OFF indicates power is lost or there is a power supply fault LED Color Indication Green Input Present 1 Red No Input Green PLL locked 2 Red PLL unlocked Green 525 Mode 4 Yellow 625 mode LED Color...

Страница 22: ...ional control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the alarm LED will flash yellow in the following continuous sequence 3 short flashes Pause 3 short flashes Use of the locate function will not interfere with th...

Страница 23: ...sion for Chroma Luma separated signals Test Built in Color Bar PLL pathological EQ pathological black flat field Performance Quantization 12 Bits for Luma and Chroma Frequency Response 0 15 dB 5 5 MHz for Luma Sampling 27 MHz 2 x over sampling Filters Selectable Chroma filters 3 line adaptive various Luma Chroma filters Processing Delay Adjustable 1 3 line delay or minimum 3 6 us S N Ratio 61 dB u...

Страница 24: ...ack controller for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount technology the module is not field serviceable The information for a replacement assembly is below C AD 5131 CardModule complete Description Ana Vid to SDI Converter Model Number C AD 5131 Part Number...

Страница 25: ...istributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this program More detailed information and product updates may be available on our web site www lynx technik com You will also find links to contact us directly for assistance ...

Страница 26: ...ed directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Phone 49 0 6150 1817 0 Fax 49 0 6150 1817 10 Website www lynx technik com E Mail info lynx technik com LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets please contact your local representative or visit our web site for more produ...

Страница 27: ...Reference Manual C AD 5131 Version1 1 Page 27 Notes ...

Отзывы: