Lynx C DA 3002 Скачать руководство пользователя страница 4

Reference Manual C DA 3002 Version 3.0

 

Page 4   

Regulatory information 

Europe 

Declaration of Conformity 
 
 
 
 
 
 
 
 
 
 
 

 
 

USA 

FCC 47 Part 15

 

  

This device complies with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause 

undesired operation. 

   

Note: This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to the part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a 

commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own 
expense

 

 

We

  

 

LYNX Technik AG 

    

Brunnenweg 

    

D-64331 

Weiterstadt 

    

Germany 

 

Declare under our sole responsibility that the product

 

  
 

 

TYPE: C DA 3002  

 

  

To which this declaration relates is in conformity with the following 
standards (environments E1-E3): 
 

 

EN 55103-1   /1996 

 

EN 55103-2   /1996 

  

EN 60950   /2001 

 

Following the provisions of 89/336/EEC and 73/23/EEC directives.

 

      

 

 

         

Winfried Deckelmann 

   
 
Weiterstadt, October 2006 

 
  Place and date of issue                          Legal Signature

 

 

 

 

                   

 

 

Содержание C DA 3002

Страница 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weizterstadt Germany www lynx technik com Reference Manual C DA 3002 Dual SDI to Analog Video Converter MiniModules V 3 0...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Страница 5: ...nnections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 16 Settings and Control 1...

Страница 6: ...Reference Manual C DA 3002 Version 3 0 Page 6 This Page is intentionally left blank...

Страница 7: ...input signal Each channel has three modes of operation using the shared connections on the front connection panel GBR YUV or S Video and composite CVBS outputs The module provides a re clocked SDI loo...

Страница 8: ...with the rack frame option and host controller The C DA 3002 is part of the 3000 series of MiniModules which offer high quality modularity and flexibility in a very small form factor ideal for applic...

Страница 9: ...BNC video connections Module configuration is set via small dip switches located behind an access hole in the bottom of the module If the module is being used in a stand alone application then the opt...

Страница 10: ...Reference Manual C DA 3002 Version 3 0 Page 10 Figure 2 Module Layout...

Страница 11: ...ectors Connection is self explanatory We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenu...

Страница 12: ...ules DC Power Connector The MiniModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the mod...

Страница 13: ...option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with one of...

Страница 14: ...05 Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules...

Страница 15: ...system Please make sure the connection is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with...

Страница 16: ...nels are identical and only one is described below Switch Settings Below the switch settings for the 6 position dip switch are defined Please see the section following the table for more detail on the...

Страница 17: ...disabled from remote LED 3 OFF please toggle Dip Switch 1 to reaquire local control Dip Switch 2 This switch selects either RGB or YUV component analog outputs from the module Only active when switch...

Страница 18: ...present ON selects signal BLACK OFF selects signal COLOR BARS Factory Preset Condition The C DA 3002 is delivered preset for the following mode of operation Local control ENABLED Composite and S Video...

Страница 19: ...ingle alarm LED on the front side of the module which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of the module is not convenie...

Страница 20: ...odule LEDs yellow in the following continuous sequence 3 short flashes Pause 3 short flashes This uses the alarm LED located on the front of the module as well as any module edge LEDs that may be used...

Страница 21: ...nal Return Loss 35dB 5 75MHz Signal to Noise 60 dB digital input black Operating Modes independent for each channel Outputs RGB or YUV or S Video and CVBS TV Standard NTSC or PAL selectable Test Inter...

Страница 22: ...ing support for 1 MiniModule R FR 3004 Mounting support for 4 MiniModules R FR 3005 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 300x or can...

Страница 23: ...001 284 Service If you are experiencing problems or have questions concerning your C DA 3002 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange pro...

Страница 24: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Страница 25: ...Reference Manual C DA 3002 Version 3 0 Page 25 Notes...

Отзывы: