background image

 

 
 
 

 

Series 3000 

© LYNX Technik AG 

Brunnenweg 3 

64331 Weizterstadt 

Germany 

 www.lynx-technik.com

 

Reference Manual 

C DA 3002  

Dual SDI to Analog Video Converter 

MiniModule

 

V 3.

Содержание C DA 3002

Страница 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weizterstadt Germany www lynx technik com Reference Manual C DA 3002 Dual SDI to Analog Video Converter MiniModules V 3 0...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Страница 5: ...nnections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 16 Settings and Control 1...

Страница 6: ...Reference Manual C DA 3002 Version 3 0 Page 6 This Page is intentionally left blank...

Страница 7: ...input signal Each channel has three modes of operation using the shared connections on the front connection panel GBR YUV or S Video and composite CVBS outputs The module provides a re clocked SDI loo...

Страница 8: ...with the rack frame option and host controller The C DA 3002 is part of the 3000 series of MiniModules which offer high quality modularity and flexibility in a very small form factor ideal for applic...

Страница 9: ...BNC video connections Module configuration is set via small dip switches located behind an access hole in the bottom of the module If the module is being used in a stand alone application then the opt...

Страница 10: ...Reference Manual C DA 3002 Version 3 0 Page 10 Figure 2 Module Layout...

Страница 11: ...ectors Connection is self explanatory We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenu...

Страница 12: ...ules DC Power Connector The MiniModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the mod...

Страница 13: ...option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with one of...

Страница 14: ...05 Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules...

Страница 15: ...system Please make sure the connection is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with...

Страница 16: ...nels are identical and only one is described below Switch Settings Below the switch settings for the 6 position dip switch are defined Please see the section following the table for more detail on the...

Страница 17: ...disabled from remote LED 3 OFF please toggle Dip Switch 1 to reaquire local control Dip Switch 2 This switch selects either RGB or YUV component analog outputs from the module Only active when switch...

Страница 18: ...present ON selects signal BLACK OFF selects signal COLOR BARS Factory Preset Condition The C DA 3002 is delivered preset for the following mode of operation Local control ENABLED Composite and S Video...

Страница 19: ...ingle alarm LED on the front side of the module which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of the module is not convenie...

Страница 20: ...odule LEDs yellow in the following continuous sequence 3 short flashes Pause 3 short flashes This uses the alarm LED located on the front of the module as well as any module edge LEDs that may be used...

Страница 21: ...nal Return Loss 35dB 5 75MHz Signal to Noise 60 dB digital input black Operating Modes independent for each channel Outputs RGB or YUV or S Video and CVBS TV Standard NTSC or PAL selectable Test Inter...

Страница 22: ...ing support for 1 MiniModule R FR 3004 Mounting support for 4 MiniModules R FR 3005 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 300x or can...

Страница 23: ...001 284 Service If you are experiencing problems or have questions concerning your C DA 3002 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange pro...

Страница 24: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Страница 25: ...Reference Manual C DA 3002 Version 3 0 Page 25 Notes...

Отзывы: