Getting Started 

Packaging 

The shipping carton and packaging materials 
provide protection for the module during transit. 

Please retain the shipping cartons in case 

subsequent shipping of the product becomes 
necessary. 

Product Description 

The C AD 5320 is a high quality dual channel 

analog audio to AES converter (A/D) and is 
designed primarily for broadcast and professional 

applications. 

  
The module accepts balanced analog audio 

inputs and converts these to 24 bit AES digital 

streams. Sampling rates of 32 kHz, 44.1 kHz, 48 kHz 
and 96 kHz are supported. The converter can be 

locked to external video reference, external AES 

reference or internal reference. Input full scale 
ranging is adjustable and an internal test tone 

generator is also provided. 
AES outputs are isolated with transformers. 

 

The C AD 5320 features a wide range of available 
adjustments (via optional Rack Controller). Basic 

adjustments are possible using via the local multi-

function switch and integrated display.  
 

CardModules are installed in the series 5000 card 

frame that can accommodate up to 10 

CardModules. All modules are hot swappable and 

Options include full redundant power and a range 

of controller options.   
 

Содержание C AD 5320 D

Страница 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual C AD 5320 D Dual Analog Audio to AES Converter CardModule Version 1 2...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exc...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...t is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful...

Страница 5: ...lanced 10 Audio Output Connector balanced 11 Audio Input Connections un balanced 11 Installation 12 Settings and Control 13 Multi Function Switch 14 Using the Local Display Menus 15 Navigation 15 Loca...

Страница 6: ...Reference Manual C AD 5320 D Version1 2 Page 6 This page is intentionally left blank...

Страница 7: ...ES digital streams Sampling rates of 32 kHz 44 1 kHz 48 kHz and 96 kHz are supported The converter can be locked to external video reference external AES reference or internal reference Input full sca...

Страница 8: ...am Figure 1 below is the basic functional diagram for the C AD 5320 CardModule Figure 1 C AD 5320 Functional Diagram Module Layout Figure 2 shows the physical layout of the C AD 5320 CardModule and al...

Страница 9: ...Reference Manual C AD 5320 D Version1 2 Page 9 Figure 2 Module Layout Caution Use static precautions when handling the PCB Static discharge could result in serious damage to the module...

Страница 10: ...ened cable to prevent the introduction of noise and interference to the audio signals twisted pair suitable for balanced audio signals Audio Input Connections balanced SubD 25 pin female connector TAS...

Страница 11: ...connections to the module NOTE When used in this manor certain technical specifications of the module cannot be maintained Figure 5 Audio wiring detail Pin Number Connection Pin Number Connection 1 9...

Страница 12: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module...

Страница 13: ...and controlled locally using the multifunction switch and 4 character dot matrix display or from remote when using one of the optional controllers and control software Once set all settings are automa...

Страница 14: ...Page 14 Multi Function Switch The CardModule is equipped with a multi function switch located on the front bottom edge of the card refer to figure 6 Figure 7 Switch Operation Up Down Enter Switch Oper...

Страница 15: ...ENTER is used to move between menu levels and also enter a selection Navigation Local Adjustments Available All of the critical adjustments to the module are accessible using the local display and mul...

Страница 16: ...back one level when selected When an item is selected which has several setting possibilities the first value displayed will be the value currently stored in the system The order of the available sett...

Страница 17: ...Reference Manual C AD 5320 D Version1 2 Page 17...

Страница 18: ...Reference Manual C AD 5320 D Version1 2 Page 18...

Страница 19: ...Reference Manual C AD 5320 D Version1 2 Page 19...

Страница 20: ...cover and provides a general indication of the module status LED OFF indicates power is lost or there is a power supply fault LED Color Indication Green Inputs and reference OK Yellow Test tone select...

Страница 21: ...ional control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selec...

Страница 22: ...ce 110Ohm Connection Female SubD 15pin connector Level 4 V p p nom Performance Sampling Sampling rates 32kHz 44 1kHz 48kHz 96kHz Quantization 24 bit Noise floor 100dB A weighted 1kHz 6dBu Distortion 0...

Страница 23: ...ntroller for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 Parts List Due to the very dense design and miniature surface mount techno...

Страница 24: ...istributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Страница 25: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik m...

Страница 26: ...Reference Manual C AD 5320 D Version1 2 Page 26 This page is intentionally left blank...

Страница 27: ...Reference Manual C AD 5320 D Version1 2 Page 27 Notes...

Отзывы: