Lynx ADP-15M Скачать руководство пользователя страница 11

LYNX  Pro  Audio  S.L.    - 

 

Valencia,  Spain  -

www.lynxproaudio.com  [email protected]

ADP-15M

11

ONLINE CONTROL SYSTEM

Who is it for?

Users of Self powered DSP incorporated Lynx Pro Audio Cabinets where the user has requested the cabinets be
supplied with the Ethernet Module kit.

What is it for?

Obtain detailed information of cabinet behaviour and monitor the cabinet/s in real time. You can change the
preset, gain, mute, polarity and phase. You can also activate the air absorption compensation and select the
«SOLO» mode.

How does it work?

Via Ethernet (cable or wireless). Once installed, the O.C.S. software automatically detects all the cabinets
connected to the network and displays them in the O.C.S. window on the users PC.

What does it show?

As well as displaying the cabinet model and IP address the O.C.S will be monitoring in real time and the user will
be able to view RMS levels, Input clip, power module temperature, compression levels, air absorption
compensation and cabinet angulation.

Содержание ADP-15M

Страница 1: ...USER MANUAL V 12 12 ADP 15M Lynx Pro Audio S L Valencia Spain www lynxproaudio com info lynxproaudio com...

Страница 2: ...ncia Spain www lynxproaudio com info lynxproaudio com ADP 15M Class D Powered bi amplified Integrated Digital Processing Internal temperature control Electronic protection High quality components Onli...

Страница 3: ...UIPMENT CE CERTIFICACTION EUROPEAN PRODUCT ADP 15M stage monitor LYNX Pro Audio S L Calle 7 Pol Ind Picassent E 46220 Picassent Valencia This user manual is property of Lynx Pro Audio S L Any reproduc...

Страница 4: ...P 15M CONTENTS SAFETY PRECAUTIONS 5 CABINET INTRO SPECIFICATIONS 6 BACK PANEL 7 CONNECTORSANDCONNECTIONS 7 CONFIGURING THE CABINET DSP OPTIONS PRESET LIST 9 FIR FILTERS 9 CONFIGURATIONPANEL 10 SELECTA...

Страница 5: ...le for operation Unplug the loudspeaker during storms or when it s being used for a long time Hearing damage risk These systems can reproduce large quantities of sound pressure which can damage hearin...

Страница 6: ...Custom Neod Nomex Cone HF 1 4 Neodimium driver Titanium diaphragm SHAPE Trapezoidal POWER AMPLIFIER 1500W Class D with Switching Power supply 750W Low Mid 750W High DSP Internal Lynxlprocessor DSPB 22...

Страница 7: ...2 3 4 5 ADP 15M BACK PANEL OUTPUTS 1 EARTH 2 LIVE 3 LIVE 1 3 2 INPUTS 1 EARTH 2 LIVE 3 LIVE 2 3 1 XLRSOCKETCONNECTORS XLRAEREALCONNECTORS Connect to output Connect to input 2 Live 3 Live 1 Earth 3 Li...

Страница 8: ...udio com info lynxproaudio com ADP 15M SOCKET POWERCON CONNECTORS L Line N Neutral Earth CONNECTION EXAMPLE 3 ADP 15M CABINETS Connect to signal output Connect toAC output CAUTION Do not connect or di...

Страница 9: ...in each one cabinet This is done via the buttons located on the back panel of the cabinet and requires electrical power to work FIR FILTERS Finite Impulse Response FIR filters are used in the signal p...

Страница 10: ...g1 If changes are not made the display will automatically dim to save energy and avoid unnecessary light in situations where light is not wanted To re activate the light simply press the OK button SEL...

Страница 11: ...e the preset gain mute polarity and phase You can also activate the air absorption compensation and select the SOLO mode How does it work Via Ethernet cable or wireless Once installed the O C S softwa...

Страница 12: ...hrough an ETHERNET SWITCH HUB You will need a normal CAT5 Cable 2 Connecting through a Wirless ETHERNET Let us now proceed to configure the Ethernet network setting the IP address of the computer as s...

Страница 13: ...ere xxx will be a number between 1 and 254 Accept to quit the network settings and again to apply them at the next screen Depending on the Windows Ver sion you will be asked to reboot or not Once the...

Страница 14: ...ate with the cabinets the software and the cabinets must have the same Network settings If it is not in the same environment Windows Profesional 2000 XP VISTA will detect it but is not going to be abl...

Страница 15: ...When we have a lot of cabinets connected in the network we can use the button Identify Device to see which box is selected two activity LEDS will blink for one second With that information then we ca...

Страница 16: ...5M If you need to know the PC Network settings go to START ALL PROGRAMS ACCESSORIES Command Prompt It will open the cmd exe from where you can type the IPCONFIG command ipconfig Enter which will show...

Страница 17: ...is already in use by another device In this case type ping IP ping 192 168 2 xxx and press enter If there is no device with this IP you will see the following information If the IP is in use the devi...

Страница 18: ...y all the necessary parts Lynx Pro Audio S L is not responsible for any damage or defect caused during the transport or caused by an undue or improper handling y a non authorized person during the lif...

Отзывы: