Specificaitons 

 

Solar Bell 

Type   

 

 

 

Wireless External Siren and strobe unit 

Housing 

 

 

 

Polycarbonate Cover 

Battery 

 

 

 

6V rechargeable battery 

 

 

 

 

 

9V alkaline battery 

Low battery detection   

5.1V 

Radio System 

 

 

433MHz transceiver 

Standby current   

 

1.0mA 

Working current   

 

< 330mA 

Siren output 

 

 

115dBA @ 1 metre 

Strobe frequency   

 

around 100/min, 60/min when siren is on, 1/min (power save mode) 

Cutoff timer 

 

 

3 min / 15 min 

 

Bell Box convertor 

Type   

 

 

 

Conversion unit between Solar Bell and Control Unit 

Housing 

 

 

 

ABS 

Voltage input 

 

 

12V DC 

Standby current   

 

25mA 

Transmitting current 

 

45mA 

Radio System 

 

 

433MHz transceiver 

Supervision  

 

 

Supervision signal monitoring 

Bell Triggering   

 

Negative (Factory preset) 

Strobe Triggering  

 

Negative (Factory preset) 

 

 

 

Page 5 

Содержание LY52-050-43

Страница 1: ... high as possible in a prominent position so that it can be easily seen and heard To provide the optimum amount of daylight to the Solar Bell in southern hemisphere such as Australia you should ideally mount the Solar Bell on a north facing wall In northern hemisphere such as UK you should ideally mount the Solar Bell on a south facing wall Shadows cast by neighbouring walls trees and roof overhan...

Страница 2: ...L Vset F L F L TAM P BELL STB GND 12V Installation 1 Select the appropriate low battery detection option by setting correct jumpers on the Bell Box convertor Fig 1 2 Mount the Bell Box convertor vertically on the wall near the control panel through the holes at the back plate of the Bell Box convertor Fig 2 Connect the wires to the control panel according to the terminals described on the above ta...

Страница 3: ...ox convertor f Set up the Cut Off Timer on the Solar Bell Fig 5 g Once the 6V lead acid 9V alkaline batteries are connected and the Solar Bell is programmed with the Bell Box convertor the unit enters the Engineering Mode for a period of 6 minutes to allow you to fit and secure the lid of the unit to its base Operation 5 Make sure to connect the Bell Box convertor with the Control Panel STB TRIG R...

Страница 4: ... so care must be taken to leave the screw head slightly proud to ensure that the microswitch remains level and closes correctly when the outer cover is fitted a If the tamper of the Bell Box convertor is triggered the tamper return signal will be transmitted to the control panel for further action b If the tamper of the Solar Bell is triggered in normal mode TAMP_OPEN signal will be transmitted to...

Страница 5: ... 330mA Siren output 115dBA 1 metre Strobe frequency around 100 min 60 min when siren is on 1 min power save mode Cutoff timer 3 min 15 min Bell Box convertor Type Conversion unit between Solar Bell and Control Unit Housing ABS Voltage input 12V DC Standby current 25mA Transmitting current 45mA Radio System 433MHz transceiver Supervision Supervision signal monitoring Bell Triggering Negative Factor...

Отзывы: