This Solar Bell (wireless bell box) operates with our Bell Box convertor, suitable for upgrading any wired 

or wireless alarm system. The Bell Box convertor can be fitted inside or near any control panel.   

 

Features 

3 minutes or 15 minutes selectable Dual Failsafe Cut-Off Timer. 

Strobe Save Mode 

The unit automatically switches to 1 flash every 60 seconds after the strobe has been flashing for 15 

minutes. The unit will revert to Normal Mode once the Control Panel has been reset (Disarmed). 

Highly sensitive light activated solar panel. No connection to main power. 

Easy to connect with any control panel. 

High intensity Xenon strobe flash.   

Fully low battery supervised. 

Operating with a 6 volt rechargeable lead acid and a 9 Volt Alkaline battery only.

 

 

Positioning the Solar Bell 

The Solar Bell should be located as high as possible in a prominent position so that it can be easily seen and 

heard. 

To provide the optimum amount of daylight to the Solar Bell, in southern hemisphere (such as Australia), you 

should ideally mount the Solar Bell on a north facing wall. In northern hemisphere (such as UK), you should 

ideally mount the Solar Bell on a south facing wall. 

 

 

 

 

 

 

 

 

 

Shadows cast by neighbouring walls, trees and roof overhangs should also be avoided. If the Solar Bell is to be 

mounted below the eaves, it should be positioned at a distance of at least twice the width of the eaves overhang 

below the eaves. Remember that in winter the sun is lower in the sky and you should avoid winter shadows 

where possible. 

The Solar Bell contains a sophisticated radio receiver. However, reception of radio signals can be affected by the 

presence of metallic objects within the vicinity of the Solar Bell. It is therefore important to mount the Solar Bell 

at a minimum distance of 1m away from any external or internal metalwork, (i.e. drainpipes, gutters, radiators, 

mirrors etc). 

 

Page 1 

Содержание LY52-050-43

Страница 1: ... high as possible in a prominent position so that it can be easily seen and heard To provide the optimum amount of daylight to the Solar Bell in southern hemisphere such as Australia you should ideally mount the Solar Bell on a north facing wall In northern hemisphere such as UK you should ideally mount the Solar Bell on a south facing wall Shadows cast by neighbouring walls trees and roof overhan...

Страница 2: ...L Vset F L F L TAM P BELL STB GND 12V Installation 1 Select the appropriate low battery detection option by setting correct jumpers on the Bell Box convertor Fig 1 2 Mount the Bell Box convertor vertically on the wall near the control panel through the holes at the back plate of the Bell Box convertor Fig 2 Connect the wires to the control panel according to the terminals described on the above ta...

Страница 3: ...ox convertor f Set up the Cut Off Timer on the Solar Bell Fig 5 g Once the 6V lead acid 9V alkaline batteries are connected and the Solar Bell is programmed with the Bell Box convertor the unit enters the Engineering Mode for a period of 6 minutes to allow you to fit and secure the lid of the unit to its base Operation 5 Make sure to connect the Bell Box convertor with the Control Panel STB TRIG R...

Страница 4: ... so care must be taken to leave the screw head slightly proud to ensure that the microswitch remains level and closes correctly when the outer cover is fitted a If the tamper of the Bell Box convertor is triggered the tamper return signal will be transmitted to the control panel for further action b If the tamper of the Solar Bell is triggered in normal mode TAMP_OPEN signal will be transmitted to...

Страница 5: ... 330mA Siren output 115dBA 1 metre Strobe frequency around 100 min 60 min when siren is on 1 min power save mode Cutoff timer 3 min 15 min Bell Box convertor Type Conversion unit between Solar Bell and Control Unit Housing ABS Voltage input 12V DC Standby current 25mA Transmitting current 45mA Radio System 433MHz transceiver Supervision Supervision signal monitoring Bell Triggering Negative Factor...

Отзывы: