The unit is intended to be mounted to an outdoor
type outlet box. The box must be supported by the
building structure and must conform to the National
Electrical Code and local electrical codes.
BULB INSTALLATION
(1) Do not touch the
bulb while it is in
use or still hot.
Allow it to cool
(about 5 minutes)
before touching it.
(2) Do not use the bulb
rated higher than 60
watts.
(3) Disconnect the
power cord or wall
switch. Unscrew
the top cover to
remove the bulb for
replacing new
bulb.(FIGURE 3)
(4) Screw back the top
cover.
FIGURE 3
INSTALLATION
To facilitate installation,
it is essential to get a
drill and a screwdriver
ready. Select a
location for the unit
based on the coverage
angles shown in
FIGURE 4.
COVERAGE ANGLES
FIGURE 4
2
Install a wall switch adjacent to the power source.
(FIGURE 5) This helps
you operate AUTO and
MANUAL OVERRIDE with ease. See page 5 for further
information.
FIGURE 5
WIRING INSTRUCTION
(1) Switch off the power source.
(2) Route the power cord through the rubber seal.
Note
: The power cord must meet H05RN-F, 3G,
1.0mm
²
requirement.
(3) Fix the wall box to the pre-determined mounting
location by making use of the two screws provided.
(4) Strip approximately 6-8mm insulating part of the
wires from the power cord. Before connection,
ensure that the wall box gasket is firmly seated in
its original place.
(5) Connect the live supply from the household
lighting circuit to the input of the wall switch.
Connect the output wire of the wall switch to the
BROWN wire in the terminal block inside the lamp
fixture base.
Connect the neutral wire of the household lighting
circuit to the BLUE wire in the terminal block.
Connect the household earth wire to the earth
position of the terminal block. (FIGURE 6a & 6b)
FIGURE 6a
3