Chapter Five--Control Setup
DMX
For DMX operation use the following steps:
The NPAC allows up to four different sets of DMX
starting addresses within a single universe.
In the fi rst set, enter the fi rst relay address. All relays
need to be assigned addresses manually. Do this by
clicking on each relay in the order you would like them
to be addressed. If you need to skip an address or
group of addresses, simply create a new zone and enter
the desired starting address. If you would like the NPAC
to automatically assign relays to consecutive addresses.
you may change that in the “Panels” tab.
Please note that selecting sACN/DMX control for a
relay or zone, will disable web browser or contact
closure control for that relay/zone. Although, relay/
zone status may still be monitored by web browser or
smartphone.
DMX and sACN are exclusive and cannot be used on the
same controller at the same time. Either can be used to
control relays in zones while other zones are controlled
by IP commands or contact closures.
Streaming ACN E1.31
For sACN operation use the following steps:
The NPAC allows up to four different universes with
sACN operation.
First, assign a number to the universe.
In the fi rst set, enter the fi rst individual relay address.
All relays need to be assigned addresses manually. Do
this by clicking on each relay in the order you would
like them to be addressed. If you need to skip an
address or group of addresses, simply create a new
zone and enter the desired starting address. If you
would like the NPAC to automatically assign relays to
consecutive addresses. you may change that in the
“Panels” tab.