Lyngdorf MP-50 – External Control Manual
16
which is always present. It will send the sound from whichever source is selected in the main
zone to zone 2.
Command !ZSRC?<CR> is used to find out which zone 2 source is currently selected. The
response for this command is !ZSRC(X)”NAME”<CR> where X is the index of the currently
selected source (0 is the first index) and NAME is the name of the currently selected source.
This response is also sent automatically, when the zone 2 source changes, if feedback level
is 1 or higher. If zone 2 is turned off, the MP-50 will reply with the previous selected source.
Commands !ZSRC+<CR> and !ZSRC-<CR> are used to select next or previous source.
Command !ZSRC(X)<CR> is used to select a specific source. The X in the command can be
anything between 0 and the index of the last source.