1 0
CONNECTORS
Mains Connector
Mains voltage to the CD-2 is applied via an IEC320 type connector. The supplied cable with safety
ground should be used to connect the CD-2 to a mains outlet.
Connect the power input only to the AC source printed on the label and the setting
shown on the voltage selector switch. The warranty will not cover any damage caused
by connecting to the wrong type of AC mains.
Always disconnect the CD-2 from the mains before changing any connections to its
inputs or outputs.
Analog outputs
The unbalanced RCA outputs are wired in accordance with normal practice:
Shell: Shield/Ground.
Pin: Hot (+).
Unbalanced analog output impedance 75 Ohm
The balanced XLR outputs are wired in accordance with IEC268:
Pin 1: Chassis and ground.
Pin 2: Hot (+).
Pin 3: Cold (-).
Shield: Chassis and ground.
Balanced analog output impedance 100 Ohm
Digital outputs
RCA output (SPDIF):
Shell: Chassis and Ground
Pin: Hot (+)
Содержание CD-2