background image

 

button for the third time, it will start the function of the current folder play; Press            button for 

the fourth time, it will play the current folder repeatly; Press            button for the fifth time, it will 

play the whole disc. 

● 

Stop play: Press 

STOP

 button to stop the play in any playing process. 

 

Installation Precautions 

1    Never block the ventilation vent. 

2    It is required to stop using immediately if the power cord is wearout. 

3    The power amplifier should not be put in the following places: 

1) 

Poor Ventilation; 

10 

2) 

Dusty and damp location; 

11 

3) 

Under direct sunlight; 

12 

4) 

High environmental temperature or near heat source; 

13 

5) 

Subjected easily to vibration;. 

14 

4    The housing should be safely grounded. 

15 

5    The power supply plug and socket should be compatible. 

16 

6    After connecting the power supply and input signal, if you hear a short alarm tone, it means that  a 

17 

short-circuit exists in the output line. It is required to cut off the power supply immediately, and the 

18 

power can only be applied after eliminating the failure. 

19 

 

20 

Performance specifications 

21 

Model No. 

PM9006 

PM9012 

PM9025 

PM9035 

Rated output 

60W 

120W 

250W 

350W 

Output adjust rate 

From full load to no load, less than 3 dB. 

Output mode 

4Ω fixed resistance output, 70V, 100V constant voltage output 

AUX output 

600Ω 0. 8V 
Mic 1, 2, 3, 4, 5 with phantom power supply (optional): 600Ω, 2.5 mV 

Input 

AUX 1, 2: 10 kΩ , 250 mV unbalance; EMC IN: The 10kΩ, 250 mV 

Frequency response    Line: 80Hz~16kHz (± 3dB); MIC: 100Hz~10kHz (± 3dB) 

Harmonic distortion  Less than 0.5% at 1kHz, 1/3 rated power 

Mic 1, Mic2, Mic3 and Mic4, Mic5: 70dB 

Signal/noise ratio 

AUX 1 and AUX2: 75dB 
Bass: ± 12dB at 100Hz 

Tone adjust 

Treble: ± 12dB at 10kHz 

Protection 

AC fuse × 1, overload, short-circuit 
Mic 1 input overlays other inputs (attenuation 0~-30dB) 

Mute function 

CHIME, EMC cover others (except Mic1) inputs (attenuation 0~-30dB) 

Built-in music source  Tuner, MP3 

Mains source 

AC 220~240V / 50 ~ 60Hz 

Power consumed 

100W 

200W 

350W 

450W 

Dimensions 

430×368×88 mm 

Gross weight 

22.5kg 

23.5kg 

25.5kg 

26.5kg 

Net weight 

21kg 

22kg 

24kg 

25kg 

No prior notice will be given if there is any alteration in the specifications. 

22 

Содержание PM9006

Страница 1: ... station tuning and saving with permanent 19 saving function at power failure 20 Chime output function 21 Two stages priority mute function available to insert the priority PA 22 The tuner MP3 status liquid crystal display LCD Chinese subtitle 5 unit LED level meters 23 inspecting the operating status very easily 24 Each channel with independent volume control treble and bass adjusting 25 100V 70V...

Страница 2: ...y screen 18 USB movable disc port 9 Remarks It means overload distortion when 5 LED are normally bright and it is necessary to adjust the 10 related volume control knob to make the 4 5th indicators flash 11 12 Back panel 13 14 15 16 17 18 19 20 21 22 23 1 FM antenna jack 7 AC 220V fuse 13 Auxiliary input AUX 2 jack 2 AM antenna jack 8 Heat radiation blower window 14 Auxiliary line 2 Microphone 5 c...

Страница 3: ...Among the four output terminals it is only appropriate to use one pair of them 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 MIC3 MIC2 MIC4 MIC5 Other SOURCE AM INT FM INT 100V 70V LINE SPEAKER LOW IMPEDANCE SPEAKER 4 ohm 8 ohm 16 ohm OPEN DISC 1 4 3 2 CD PLAYER 00 35 TAPE RECORDER ...

Страница 4: ... priority and its signal overlays all the input 25 signals from other ports The chime and the EMC port has the second highest priority and its 26 signal overlays all the other signals except Microphone 1 including Microphone 2 and 27 Microphones 3 28 3 Chime This equipment is provided with Chime 1 and Chime 2 signals and the chime volume 29 can be adjusted by the chime adjusting knob at the back p...

Страница 5: ... downward adjusting and M UP button is for upward 23 adjusting For example if you want to save frequency 107 65 to the 18th saving number but 24 when you press the MEMO button the screen displayed is the 19th saving number then you 25 press M DOWN button and press again MEMO button at this time to save the band of 26 frequency 107 65 to the 18th saving number 27 2 The setup operation of MP3 play m...

Страница 6: ...ly immediately and the 18 power can only be applied after eliminating the failure 19 20 Performance specifications 21 Model No PM9006 PM9012 PM9025 PM9035 Rated output 60W 120W 250W 350W Output adjust rate From full load to no load less than 3 dB Output mode 4Ω fixed resistance output 70V 100V constant voltage output AUX output 600Ω 0 8V Mic 1 2 3 4 5 with phantom power supply optional 600Ω 2 5 mV...

Страница 7: ...ug from the socket The equipment should not suffer from the drop of water or water splash and it is not allowed to place object such as vase filled with water on the equipment Please do not open at will the machine cover plate to prevent electric shock Certified professional personnel are required to undertake the repair when it is needed 1 2 LY INTERNATIONAL ELECTRONICS CO LTD 3 ...