Notice 1. +24V DC (ALL CALL) output power is sent to the RELAY of the volume controller.
2. “+24V DC
(
(
(
(
ALL CALL
)
)
)
)
”output is controlled by the “ALL” button on the front panel.
SYSTEM CONNECTION
Speaker output terminals are on the rear panel. The terminal under the label “COM” is COMMON. The
terminals under the labels “4
Ω
, 70V, 100V” are Hot. The connection should be COM-4
Ω
/ COM-70V /
COM-100V.
Normally the “rated power” (70V / 100V) output terminal is used in output connection. The connected
speaker should have a matching transformer, and the gross power of speakers should be less than the
rated power of the amplifier.
“Rated Impedance”(4
Ω
) output terminal can be used when speakers are fixed closely, and the gross
impedance of speakers should be 4