27
to select the first ID which will start, then main unit send the ID coding
information to microphone, all microphone OLED display will show “ ID
SETTING: 001?”, press key
on that microphone if u confirm the ID, and
then this microphone OLED display will show “ID=001” and main unit will
auto-generate the next ID number, the rest of mic OLED display will show
the new ID “ID SETTING: 002?” , press key
on that microphone if u
confirm the ID, please finish all microphone ID setting step by step and press
“Menu/BACK” key to back, system will exit and save the current setting
automatically.
Option 2: Turn off microphone power first, hold and press “ Menu” key and then turn on
the microphone power, microphone OLED display will show ID setting
interface, please use key ( ) or ( ) to select the ID and exit by key
“MENU/BACK”
Main unit display
Microphone display
h. System detecting: User can set the best microphone position with the help of this mode
Method to setting:Press “ Menu” key, and press key (
) seven times switch to system
setting interface, and then press key
to enter, please turn on the microphone
when you debug the microphone position. TSQ (Microphone transmission signal) and
RSQ ( microphone receiving signal ) can not be 0, the number is bigger, the mic
position is better, TPW is the microphone current TX power, system will debug the TX
power according to the transmission signal level automatically to optimize the
communication, Automatic adjustment level is 10dB.
Main unit display
Microphone Display
i. Communication checking: User can detect the data communication between main unit
and microphone with the microphone ID number.
Method to checking:Press “ Menu” key, and press key (
) eight times switch to
system communication checking interface, and then press key
to enter, press (-)
or (+) to select the first ID, if the main unit numerical value of data same as
microphone numerical value (001-015 circulatory), without any break, it means the
communication between main unit and microphone is good.