background image

 

4

 

Cleaning: 

 

You can clean the exterior of the unit with compressed air or a damp cloth.  

 

Don’t clean the unit using solvents like trichloroethylene, thinners, alcohol, or other volatile or flammable fluids. 

 

Non use periods: 

The unit AC power cable should be unplugged from the outlet if it’s unused for long periods. 

 

Objects or liquid entry into the unit: 

Be careful that no objects fall into the unit or that no liquid is spilled inside the unit through ventilation openings.  

 

Safe power line use: 

 

Hold the plug and the wall outlet firmly while disconnecting the unit from AC power. 

 

When the unit will not be used for a long period of time, please unplug the power cord from AC power outlet.  

 

To avoid power cable damage, don’t strain the AC power cable and don’t bundle it.  

 

In order to avoid damage to the unit's power cable,  be sure that the power cable is not walked on or pinched by 
heavy objects.  

 

Unit relocation:

  

Before  relocating  the  unit,  please  control  the  unit  is  turned  off.  The  power  cord  must  be  unplugged  from  the  wall 
outlet, and all the connecting cables should be disconnected as well. 

 

Do not open this unit:  

Do  not  attempt  to  open  or  repair  this  unit  yourself.  For  any problem  not  described  in  this  owner’s manual,  please 
refer to qualified personnel only or consult us or your National Distributor. Any improper operation could result in fire 
or electric shock. 

 

Damages requiring services: 

 

Do not attempt to perform operations not described in this user’s manual.  

 

In the following cases please refer to an authorized service center or skilled personnel:  

- When the unit works improperly or it doesn’t work at all.  
- If power cord or plug is damaged.  
- If liquid has spilled, or objects have fallen into the unit.  
- The unit has been exposed to rain.  
- The unit doesn’t operate normally or exhibits a marked change in performance.  
- If the product has been dropped or has been damaged in any way.  

 

Maintenance:  

The user shouldn’t attempt maintenance not described in this user’s manual.  All maintenance should be performed 
by qualified personnel only. 

 

IMPORTANT SAFETY INSTRUCTIONS:  

 

Install this unit following owner’s manual instructions.  

 

Do not install, connect or disconnect  power  supply when the unit is powered,  otherwise there is a high risk of 
electric shock.  

 

Do not open the unit, there are no user serviceable parts inside.  

 

If you detect a particular smell from the unit, please immediately turn it off and disconnect the AC power cord.  

 

Don’t block the unit's ventilation openings.  

 

Avoid using this unit in overload for a long period.  

 

Don’t force commands (switches, controls, etc.)  

 

To obtain good speaker wire contact, please tighten the screw terminals firmly. 

 

 

For safety reasons, do not defeat the grounding connection. Grounding is for user safety. 

 

Use only connectors and accessories suggested by the manufacturer. .  

 

This unit should be fitted in an equipment rack (see INSTALLATION) and kept far from:  

  Wet places  

  Direct exposure to heat sources (like sun light) 

  Improperly ventilated places 

 

Disconnect the power cord during storms or when the unit is not in use. 

 

   In order to prevent fire and reduce risk of electric shock, it is necessary to keep the unit far from dripping 

water. Please don’t put cups, vases or other object containing liquids over the unit. In case of interference from 
source signal, THD value will raise over 10%. Don’t place this unit in a bookshelf or in other enclosed spaces.  

 

We are not responsible for any damage that occurs due to a incorrect installation of the unit. 

 

 
 

Содержание H-3800C

Страница 1: ...INSTRUCTION MANUAL Digital Conference System H 7000D H 3800c H 3800d ...

Страница 2: ...ION 5 3 FRONT PANEL FUNCTIONS AND CONTROLS H 7000D 5 4 REAR PANEL FUNCTIONS AND CONTROLS H 7000D 6 5 PRESIDENT H 3800c AND DELEGATE H 3800d UNIT FUNCTIONS AND CONTROLS 6 6 CONNECTION 7 7 HOW TO USE THE SYSTEM 9 8 PACKAGE CONTENTS 9 9 TECHNICAL FEATURES 9 ...

Страница 3: ...and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUCTIONS Water and moisture This apparatus should not be used near water i e bathtub kitchen sink swimming pools etc Ventilation This apparatus should be placed in a position that doesn t interfere with its correct ventilation This unit for example...

Страница 4: ...ug is damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain The unit doesn t operate normally or exhibits a marked change in performance If the product has been dropped or has been damaged in any way Maintenance The user shouldn t attempt maintenance not described in this user s manual All maintenance should be performed by qualified personnel only IM...

Страница 5: ...r a maximum of 30 stations on each line The serial connection of each station is achieved through single multicore prerouted cables that may be used either for fixed or mobile systems Main Functions It directly powers and controls 64 microphone stations President station has priority on others Five operating modes FREE MODE LIMIT 1 2 3 5 One microphone input MIC and one line input LINE for externa...

Страница 6: ...utput male XLR3 Connect mixer or amplifier to this output 10 DELEGATES Unbalanced signal output RCA Left and right channel 11 TEL IN OUT Connect telephone coincidence to support telephone meeting 12 DATA RJ45 interface use for connect video processor to support video tracking function 13 TREBLE GAIN Rotate this control counterclockwise to emphasize high frequencies 14 AC POWER SOCKET Power 230VAC ...

Страница 7: ...tations has been reached Press again to turn off microphone 7 PRIORITY Press this button on the PRESIDENT station to disable all other speaker stations 6 CONNECTION Connect the unit to 230 V AC 50 60 Hz mains Use the connection cables provided to connect the daisy chained stations to the 4 BASE INPUTs figure 2 ref 8 as shown in figure 3 paying attention not to connect more than 30 stations to each...

Страница 8: ...TIONS Balanced connection Unbalanced connection Balanced connection with TRS jack Unbalanced connection with TRS jack Balanced connection on EUROBLOC connector Unbalanced connection on EUROBLOC connector RCA Connection ...

Страница 9: ...able H 3800d 1x Base 1x Gooseneck microphone 1x connection cable 9 TECHNICAL FEATURES Model H 7000D H 3800c H 3800d BASES 8P DIN socket n 4 BUS BAL OUT Balanced XLR3Male MIX Unbalanced RCA L R S N Radio 75 dB 75 dB Frequency Response 20 Hz 18 kHz 20 Hz 18 kHz Sensitivity 44 2dB T H D 0 05 0 05 Dimensions WxHxD 482x45x353 mm 1U standard 19 rack Base 130x160x50 mm Gooseneck 420 mm Weight 5 kg 0 9 kg...

Отзывы: