LXI 60-850 Скачать руководство пользователя страница 3

LXI Fiber Optic Multiplexer – 60-850/851

pickering

test

.com

Specifications

Operating/Storage Conditions

Operating Conditions

Operating Temperature: 

Humidity: 

Altitude:

0°C to +55°C 

Up to 95% non-condensing 

5000m

Storage and Transport Conditions

Storage Temperature: 

Humidity: 

Altitude:

-20°C to +75°C 

Up to 95% non-condensing 

15000m

Safety & CE Compliance

All modules are fully CE compliant and meet applicable EU 

directives:  Low-voltage safety EN61010-1:2010, EMC Immunity 

EN61326-1:2013, Emissions EN55011:2009+A1:2010.

Mechanical Characteristics

Supplied with front panel ears to enable rack mounting on a shelf or 

other rear support mechanism.
Dimensions: 

1U high, full rack width, 340mm depth

3D models for all versions in a variety of popular file formats are 

available on request.

Cooling

Fan assisted cooling, side air intakes and rear exhaust.

LAN Interface

Compliant to LXI Standard 1.4, the 60-850/851 has a 1000Base-T 

Ethernet Interface via a standard RJ-45 connector mounted on the 

rear panel with an LCD display showing the unit’s IP address*. 

*Note: Legacy units may not have 1000Base-T support or be fitted 

with an LCD display.

LXI Status Indicators

Front panel mounted LEDs:

•  Power
•  Ready
•  Error
•  LAN
•  Active

Switch Indicators

LED indicators show the selected MUX channel.

Connectors

Signals via front panel connectors as Product Order Codes.

Connector Protection

Supplied with tethered dust caps for use when not connected to an 

external fiber connector.

Power Source

Universal AC mains supply, 90-264VAC, 50-60Hz
Power Inlet:

Male IEC connector 

on rear panel

Single-Mode Specification

Fiber Switch Type:

MEMS

Available Connector Types:

FC/APC, FC/PC, SC/PC, 

MU, LC.

Wavelength:

1240nm to 1640nm

Internal Fiber Type:

SM 9/125

Insertion Loss:

1dB typ (8:1 version) 

1.5dB typ (16:1 version) 

1.5dB typ (8:1 loop-thru) 

2dB typ (16:1 loop-thru) 

2.5dB typ (32:1 version)

Return Loss:

60db min (APC version) 

55dB min (other versions)

Polarization Dependent Loss 

(PDL):

0.05dB max

Repeatability:

±0.01dB max 

Crosstalk:

-60dB max

Recommended Input Power:

+20dBm Above this level a 

small increase in insertion 

loss may be experienced, 

typically less than 0.1dB 

at +27dBm. Damage level, 

>+30dBm continuous.

Thermal Stability (-10 to 75°C 

insertion loss variation):

 

0.2dB max

Expected Life:

>>10

9

 operations

Maximum Switching Time:

1ms

Cycle Rate:

500/sec

Multi-Mode Specification

Fiber Switch Type:

MEMS

Available Connector Types:

SC, ST

Wavelength:

700nm to 1700nm

Internal Fiber Type:

MM 62.5/125

Insertion Loss:

1dB typ (8:1 version) 

1.5dB typ (16:1 version) 

1.5dB typ (8:1 loop-thru) 

2dB typ (16:1 loop-thru) 

2.5dB typ (32:1 version)

Return Loss:

55dB min

Polarization Dependent Loss 

(PDL):

 

0.05dB max

Содержание 60-850

Страница 1: ...ing technology to ensure fast and reliable switching of single mode 60 850 or multi mode 60 851 optical signals being carried on fiber connections The 60 850 851 is available with a variety of connector options and in a variety of multiplexer arrangements Multiplexer configurations offered are single 8 channel dual 8 channel single 16 channel and single 32 channel Each configuration can be supplie...

Страница 2: ...n Example Configuration using the Loop Thru Connection Two 60 850 851 16 Channel Multiplexers can be cascaded to produce a single 32 Channel Optical Multiplexer 32 Channel Multiplexer Ch 9 Ch 10 Ch 11 Ch 12 Ch 13 Ch 14 Ch 15 Ch 16 Ch 17 Ch 18 Ch 19 Ch 20 Ch 21 Ch 22 Ch 23 Ch 24 Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 Ch 7 Ch 8 Ch 25 Ch 26 Ch 27 Ch 28 Ch 29 Ch 30 Ch 31 Ch 32 Common Loop Thru Switching Diagra...

Страница 3: ...cators LED indicators show the selected MUX channel Connectors Signals via front panel connectors as Product Order Codes Connector Protection Supplied with tethered dust caps for use when not connected to an external fiber connector Power Source Universal AC mains supply 90 264VAC 50 60Hz Power Inlet Male IEC connector on rear panel Single Mode Specification Fiber Switch Type MEMS Available Connec...

Страница 4: ...plexer FC APC Single Mode FC APC Single Mode with Loop Thru SC Single Mode SC Single Mode with Loop Thru LC Single Mode LC Single Mode with Loop Thru SC Multi Mode SC Multi Mode with Loop Thru 60 850 013 60 850 023 60 850 213 60 850 223 60 850 413 60 850 423 60 851 213 60 851 223 Single 32 Channel Fiber Multiplexer FC APC Single Mode FC APC Single Mode with Loop Thru SC Single Mode SC Single Mode ...

Страница 5: ...rs to complex cables assemblies and terminal blocks All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules Connectors Backshells Multiway Cable Assemblies RF Cable Assemblies Connector Blocks Programming All LXI devices are supplied with built in software drivers web pages for configuration and soft front panels as required by the LXI s...

Страница 6: ... To learn more please go to pickeringtest com ebirst Three Year Warranty All standard products manufactured by Pickering Interfaces are warranted against defective materials and workmanship for a period of three years from the date of delivery to the original purchaser Extended warranty and service agreements are available for all our modules and systems with various levels to suit your requiremen...

Отзывы: