![LW MEASUREMENTS TREE PIZA+ 12 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/lw-measurements/tree-piza-12/tree-piza-12_instruction-manual_1953073006.webp)
When to calibrate
Note: Calibration is done in factory. Don't re-calibrate the Scale, unless it is not
accurate.
Calibration:
A. Turn on the power switch of the scale
,
Press and hold
[ZERO]
key then press
[ON/OFF]
, the display
will show
“CAPU=”
, press twice
[HOLD]
key, the display will show
CALU=
, press
[UNIT]
key to select
calibration unit kg or lb, it will have a small triangle on the right to indicate kg or lb, press
[HOLD]
key
to confirm the selection.
B. Press
[HOLD]
key again, the display will show
CAL
, press
[UNIT]
key to
set calibration weight. Press
[UNIT]
key to move the flash digit to right, then
press
[ZERO]
key to increase the flash digit, press
[HOLD]
key to confirm
the selection ( the calibration weight should be more than
2/3
of full
capacity), it will show CAL.
C. Press
[PRINT]
, it will show CAL and AD value.
D. Press
[UNIT]
key, the display will show the flash calibration weight, place the shown weight on the
platform, press
[UNIT]
key when the stable indicator brightens up, the display will show “
--------
”, then