LW MEASUREMENTS TREE LCT 110 Скачать руководство пользователя страница 7

 

1 Safety 

 

1.1 Representations and symbols 

 
Important instructions, which involve safety, are highlighted with the appropriate mark: 
 

 

 
 

1.2 Safety recommendations 
 

When using the weighing equipment  in surroundings with increased safety requirements, the 
corresponding regulations must be observed. 
 
The weighing machine may only be used with the power adapter supplied exclusively for use with the 
weighing machine. 
 
Before inserting the power adapter, the user must ensure that the operating voltage stated on the power 
adapter agrees with the mains voltage. 
 
If not, please contact Customer Service at the address above. 
 
If the power adapter or its cable is damaged, the weighing machine must immediately be disconnected 
from the electricity supply (pull out the power adapter).  
 
The weighing machine may only be operated from mains electricity supply with a power adapter which is 
in perfect condition. 

 

If there should be any reason to believe that it is no longer possible to operate the weighing machine 
without danger, the weighing machine is to be immediately unplugged from the electricity supply (pull out 
power adapter) and secured against inadvertent operation. 
 
In carrying out maintenance work, it is essential to follow the recommendations in Chapter 6 Maintenance 
and service. 
 
The weighing machine must not be operated in an area subject to explosion risks. 
 
Care must be taken when weighing liquids to ensure that no liquid is spilt into the inside of the weighing 
machine or into connections on the rear of the equipment or the power adapter. If liquid is spilt on the 
weighing machine, it must immediately be unplugged from the mains electricity supply (pull out power 
adapter). 
The weighing machine may only be operated again after it has first been re-checked by a service 
technician. 
 
These operating instructions must be read by each operator of the equipment and must be available at 
the workplace at all times. 
 
 
 

 

Содержание TREE LCT 110

Страница 1: ...1 Professional Weighing Equipment LCT SERIES intelligent weighing machine LARGE COUNTING SCALE WITH CHECK WEIGHING FUNCTION Operating Manual...

Страница 2: ...ollowing standards Electronic scale LCT Large Counting Scales Mark applied EU Directive Standards 2004 108 EC EN 61326 1 2006 Date 14 11 2012 Signature Boon Lim R D Manager LW Measurements LLC 3510 In...

Страница 3: ...Europe Ltd Chalkwell Park House 700 London Road Westcliff on Sea Essex SS0 9HQ United Kingdom Tel 01702 476700 Fax 01702 477380 ASIA LW Measurements PTY Ltd Block 1004 Toa Payoh North 03 16 Singapore...

Страница 4: ...ing instructions in their entirety so that you can make optimum use of the full potential and the diverse possibilities of the weighing machine in your daily work These operating instructions contain...

Страница 5: ...machine 3 1 Unpacking the equipment 3 2 Scope of delivery 3 3 Assembling your weighing machine 3 4 Choice of a suitable location 3 5 Checking the mains voltage 3 6 Leveling the weighing machine 3 7 C...

Страница 6: ...ating the acoustic signal 4 2 2 8 Activating the display backlight 4 2 2 9 Automatic stand by 4 2 2 10 Memory storage 4 2 2 11 Total weight clear 5 Calibration using an external calibration weight 6 M...

Страница 7: ...pter which is in perfect condition If there should be any reason to believe that it is no longer possible to operate the weighing machine without danger the weighing machine is to be immediately unplu...

Страница 8: ...1 Construction and functions 2 1 1 Construction of the weighing machine The weighing machine consists of the weighing machine body 1 the scale pan 2 the adapter 3 and this operating manual 2 Figure 2...

Страница 9: ...Model number Capacity Graduation Weighing pan Size LCT 3 3 lb 0 0001lb 227x337mm LCT 7 7 lb 0 0002 lb 227x337mm LCT 16 16 lb 0 0005 lb 227x337mm LCT 33 33 lb 0 001 lb 227x337mm LCT 66 66 lb 0 002 lb...

Страница 10: ...ly for simple weighing but also for carrying out various weighing applications such as primarily component counting weighing and the communication function enables the user to document the measurement...

Страница 11: ...11 Figure 2 2 Details of your weighing machine Weighing pan Battery compartment cover Intelligent key pad Bright back lit display Battery compartment Bubble level Mains power connection Leveling feet...

Страница 12: ...st be observed 2 2 2 Conformity The weighing machine has been manufactured and tested in accordance with the standards and recommendations set out in the declaration of conformity The power adapter pr...

Страница 13: ...hours in the unopened transport package in a dry room at normal temperature so that no condensation settles on the unit when unpacking Check the weighing machine immediately after unpacking for extern...

Страница 14: ...he surface should not be magnetic and should be located away from doors windows heaters air conditioners and fans To summarize Put the weighing machine on a solid firm and preferably vibration proof h...

Страница 15: ...ligned with the red circle See Fig 1 In order to get exact measurements the balance must again be carefully leveled after each relocation Fig 1 Correct leveling with the aid of the bubble level ER 3 7...

Страница 16: ...ght is not significant enough for accurate counting 4 1 2 Key Functions 1 The ZERO key allows the subtraction of multiple container values through the weighing range and is used to set or re adjust th...

Страница 17: ...y or using a container do not forget to tare the container weight first The total weight is displayed Enter the corresponding number of samples for example 10 units using the numeric keys and press th...

Страница 18: ...ut counting error might occur 4 2 2 5 High Low check weighing with counting THE LCT series has a useful check function to give guidance to the operator that the total piece count quantity is below a p...

Страница 19: ...4 2 2 10 Memory storage Turn on the scale Select the unit kg or lb for the storage of unit weigh by pressing SAMPLE UNIT key Key in the unit weight value through data 0 9 then press STORE to confirm...

Страница 20: ...hird line Press SAMPLE UNIT to select calibration unit kg or lb After the stable A D value is displayed press ZERO after 2 or 3 seconds the scale will show 0 Key in calibration weight through numeric...

Страница 21: ...n after it has first been checked by a service engineer The connections on the rear of the appliance and the power adapter may not come into contact with liquids Regularly dismantle the weighing pan a...

Страница 22: ...ld like to take the weighing machine out of service for an extended period disconnect it from the electricity supply clean it thoroughly see Section 6 Maintenance and servicing and store it in a place...

Отзывы: