background image

 

16

 

 

POS.

 

CODE

 

DESCRIPTION

 

1

 

AC000_M031_001

 

PNEUMATIC

 

MAST

 

WITH

 

MANUAL

 

PUMP

 

2

 

LUX

 

S10_C000_113

 

MANUAL

 

PUMP

 

STOP

 

PLATE

 

3

 

LUX

 

S10_C000_112

 

MANUAL

 

PUMP

 

SUPPORT

 

4

 

LUX

 

S10_C000_007

 

STABILIZER

 

COMPARTMENT

 

5

 

LUX

 

S10_C004_056

 

COVER

 

6

 

LUX

 

S10_C004_001

 

SUPPORT

 

BASE

 

7

 

AC000_P037_016

 

RUBBER

 

FOOT

 

8

 

LUX

 

S10_C000_018

 

WHEELS

 

SUPPORT

 

9

 

LUX

 

S10_C000_019ZN

 

WHEEL

 

SPACER

 

10

 

AC000_M000_128

 

WHEEL

 

11

 

AC000_E000_071

 

5

 

POLES

 

CONNECTOR

 

12

 

LUX

 

S10_S010_033B

 

TARGA

 

DATI

 

13

 

AC000_E011_018

 

230V

 

16A

 

SCHUKO

 

INLET

 

14

 

AC000_E011_016

 

230V

 

16A

 

SCHUKO

 

PLUG

 

15

 

AC000_E000_037

 

LAMP

 

SWITCH

 

COVER

 

16

 

LUX

 

S10_C000_119

 

CONTROL

 

PANEL

 

BOX

 

17

 

LUX

 

S10_C006_033

 

LAMP

 

SWITCH

 

FRAME

 

18

 

AC000_E012_027

 

LAMP

 

SWITCH

 

19

 

LUX

 

S10_C006_034

 

LAMP

 

SWITCH

 

SUPPORT

 

20

 

LUX

 

S10_C000_011

 

REAR

 

COVER

 

21

 

LUX

 

S10_C004_110

 

COVER

 

22

 

AC000_I025_022

 

CURVED

 

CONNECTOR

 

23

 

AC000_I025_021

 

PIPE

 

FITTING

 

24

 

AC000_M000_064

 

MAST

 

SUPPORT

 

25

 

LUX

 

S10_C000_023ZN

 

PLATE

 

26

 

LUX

 

S10_C004_004

 

TOP

 

FRAME

 

27

 

LUX

 

S10_C007_005

 

ROUND

 

HANDLE

 

28

 

LUX

 

S10_C000_055

 

WHEEL

 

WITH

 

BRAKE

 

SUPPORT

 

29

 

AC000_M000_192

 

WHEEL

 

WITH

 

BRAKE

 

30

 

LUX

 

S10_C000_064ZN

 

FLOODLIGHTS

 

HOLDER

 

CHAIN

 

SECTION

 

 
 

 

SPARE PARTS 

Содержание LUX S10

Страница 1: ...LIGHTWEIGHT MOBILE LIGHTING TOWER 6x50W LED USER MANUAL Model LUX S10 A0012 User s manual MI800A00012 Rev 00 Date 16 09 2019 ...

Страница 2: ...t at time of approval for printing Please consider that this manual may refer to controls and optional equipment that are not present on your particular machine It is important that you know your machine and its equipment and how to operate it properly so please read the operating instructions carefully and understand them before operating the machine Machine specifications can be modified at any ...

Страница 3: ... MACHINE IDENTIFICATION 7 TECHNICAL DATA 8 LIGHTING TOWER COMPONENTS 9 LIGHTING TOWER USE 10 LIGHTING TOWER POSITIONING 10 STABILIZING THE UNIT 10 DIRECTING THE FLOODLIGHTS 11 SWITCH ON THE FLOODLIGHTS 11 ADJUST THE MAST HEIGHT 12 LOWER THE MAST 12 MAST MAINTENANCE 13 SPARE PARTS 14 ELECTRICAL DIAGRAM 18 WARRANTY 20 TABLE OF CONTENTS ...

Страница 4: ...Follow the correct procedures in the event of heavy rain or electrical storm Lower tower when not in use or if high winds or electrical storms are expected in the area Use protective clothing and safety equipment gloves safety boots safety hard hat goggles ear protection and dust masks when necessary Know all side clearances and overhead obstructions for safe operation of the machine ALWAYS make s...

Страница 5: ...oting or repairing any electrical circuit Only a qualified electrician should troubleshoot or repair electrical problems occurring on the machine Disconnect electrical power before removing protective covers on high voltage electrical closures NEVER allow water to accumulate at the base of the machine If water is present DO NOT service DO NOT service electrical components if your clothing or skin ...

Страница 6: ...stickers meanings Attention Read user s manual before operating the machine Attention high voltage Read user s manual before operating the machine Attention Danger of crushing SAFETY RULES SAFETY STICKERS GUIDE ...

Страница 7: ...rm to directives and fulfill all the relevant safety requirements Type Lamps Hz Dimensions L x W x H Weight SERIAL N V W Power inlet V A Hz TECHNICAL SPECIFICATIONS MACHINE IDENTIFICATION 1 Manufacturer s address 2 Manufacture year 3 Machine model 4 CE Logo 5 Lamps rated voltage 6 Lamps rated power 7 Lamps frequency 8 Power inlet rated voltage 9 Power inlet rated current 10 Power inlet rated frequ...

Страница 8: ...uminated area 1900 sqm Operating temperature range 30Ԩ 45Ԩ Voltage 230V Frequency 50Hz MAST Lifting method Pneumatic Maximum Height 4 3 m Maximum Wind Speed 110 km h Rotation 360 GENERAL Weight 83 kg DIMENSIONS 1450 mm 2372 mm 2058 mm 440 mm 404 mm 520 mm TECHNICAL SPECIFICATIONS TECHNICAL DATA ...

Страница 9: ... manual handling 3 Adjustable stabilizers with tensioner 4 Locking pins for stabilizers 5 Control panel 6 Data plate 7 Lamps switch 8 230V 16A SCHUKO output 9 230V 16A SCHUKO Mains inlet 10 Mast lifting manual pump 11 Wheels for manual handling 12 Condensation water exhaust valve 13 Air exhaust valve 11 12 13 ...

Страница 10: ...mum light coverage and illumination efficiency locate the unit at ground level or in a spot higher than the area being illuminated by the lamps Do not move the tower with the mast raised Stabilizing the unit as follows Hold the stabilizer with one hand and pull the locking pin to release it Pull the stabilizer outward and resting it on the ground picture A Secure the tensioner 1 to the pin 2 Adjus...

Страница 11: ... to fan manually A Each LED can be tilted forward manually B This way the floodlights can be directed either vertically or horizontally Connect the unit to the mains using the plug 2 Switch on the floodlights using the switch 1 LIGHTING TOWER USE DIRECTING THE FLOODLIGHTS SWITCH ON THE FLOODLIGHTS A B 1 2 ...

Страница 12: ... until the operation is complete Lock all the handwheels ATTENTION In case of particularly rigid temperatures difficulties can occur in the complete lowering of the column for internal ice formation Normally the weight mounted on the top of the column is sufficient to remove the possible presence of ice Otherwise use simple denatured ethyl alcohol in the area of the terminal rings at the end of ea...

Страница 13: ...re verifying the presence of air leaks deterioration of the surfaces for oxidation attack or abrasion WINTER USE In the winter period it is necessary to empty the condensate water that can form inside the column this operation must be carried out at the end of the application with a lowered column Remove the valve see picture to allow the drain condensation water LIGHTING TOWER USE MAST MAINTENANC...

Страница 14: ...14 SPARE PARTS ...

Страница 15: ...15 2 3 4 5 6 7 8 9 10 20 11 12 13 14 15 16 17 18 19 21 22 23 24 25 30 39 40 38 37 36 32 33 31 26 27 28 29 1 41 42 1 54 53 52 51 50 49 45 44 46 47 48 43 34 35 55 56 57 58 59 60 61 62 63 64 SPARE PARTS ...

Страница 16: ...C000_E011_018 230V 16A SCHUKO INLET 14 AC000_E011_016 230V 16A SCHUKO PLUG 15 AC000_E000_037 LAMP SWITCH COVER 16 LUX S10_C000_119 CONTROL PANEL BOX 17 LUX S10_C006_033 LAMP SWITCH FRAME 18 AC000_E012_027 LAMP SWITCH 19 LUX S10_C006_034 LAMP SWITCH SUPPORT 20 LUX S10_C000_011 REAR COVER 21 LUX S10_C004_110 COVER 22 AC000_I025_022 CURVED CONNECTOR 23 AC000_I025_021 PIPE FITTING 24 AC000_M000_064 MA...

Страница 17: ...IRAL CABLE 44 AC000_M000_134 TENSIONER 45 LUX S10_C000_015 BUSHING FOR TENSIONER 46 AC000_M000_132 KNOB 47 AC000_M000_133 SPRING 48 AC000_M000_131 PIN 49 LUX S10_C000_009ZN STABILIZER FOOT PART 2 50 LUX S10_C000_116ZN STABILIZER PART 2 51 LUX S10_C000_115ZN STABILIZER PART 1 52 LUX S10_C000_014 BUSHING 53 LUX S10_C000_013 SPACER 54 LUX S10_C000_032 LOGO PLATE 55 AS000_M023_025 SPACER 56 AS000_E006...

Страница 18: ...18 ELECTRICAL DIAGRAM ...

Страница 19: ...19 ELECTRICAL DIAGRAM ...

Страница 20: ... will not be held responsible if the machine has been used to perform tasks that it has not been designed for the machine has undergone modifications not approved by the company conditions of use have been abnormal normal maintenance compliant to requirements as set out by the manufacturer have not been adhered to No payment or expenses refund should be pretended from the manufacturer for normal m...

Отзывы: