The direct current generated by photometric systems 

can be converted into alternating current and fed into 

the local grid. As the grid operators have different 

infeed conditions from town to town for the connec-

tion of renewable energy systems, contact with the 

responsible grid operator should be made in due 

time. Approvals for the installation of such a system 

are usually required (application for grid connection). 

Connection to the grid may only be carried out by a 

licensed electrician. 

 

 Please refer to the valid module datasheet 

for detailed module data. The electrical rated 

parameters of the modules are also stated 

on the module type plate.

4.2 Earthing

  

Caution!  

Danger of material damage!

 

 Please observe the local regulations and 

provision for earthing.

  

Caution!  

Danger of material damage!

 

 Bolts, screws or other earthing connections 

may not be used to fasten the module to the 

assembly rack.

The modules have two holes (2 mm) on the back for 

fastening the potential equalisation in the module 

frame. 

4.3 Cabling

 

Caution!  

 

Danger of electric shock!

 

 Please observe the safety instructions for 

working with direct current!

  

Caution!  

Danger of electric shock and burns!

 

 Do not disconnect the plug-in module con-

nections under load! Otherwise non-extin-

guishing electric arcs may result.

The modules are pre-conditioned with fixed cables 

and MC4 plug connections. Only use suitable and 

!

!

Содержание eco line 60/225-235W

Страница 1: ...ECo line Modules correctly mounted...

Страница 2: ...Table of contents...

Страница 3: ...3 20 Information regarding this manual Safety instructions Mechanical installation Electrical installation Troubleshooting maintenance 04 06 07 08 09 13 14 16 17 19...

Страница 4: ...stood prior to installation In case of any questions please contact our sales department for further explanations During installation of the module the installer must adhere to all safety precautions...

Страница 5: ...her third party rights resulting from the use of the PV product A license under a patent or patent rights shall not be granted neither by implication nor by any other way The information in these inst...

Страница 6: ...local grid operators Regional building regulations 1 8 Product identification Each module has labels on the back containing the following information Identification label describes the product type r...

Страница 7: ...the total current strength corresponds with the total of the current strengths of the individual modules Even contact with a direct current voltage Safety instructions of 30 volts or higher is potenti...

Страница 8: ...entrate the sunlight onto the modules Do not expose the rear film to direct sunlight Do not use the module near equipment or in places where flammable gases are generated or may accumulate Do not dril...

Страница 9: ...s should be orientated towards the south and vice versa You will find detailed information about the best angle of inclination for installation in specialised literature or from an experienced solar i...

Страница 10: ...entilation hole d 7 mm C 8 x mounting hole d 7 mm D 2 x earthing d 2 mm 3 2 Dimensional module drawings Rear front side view Eco Line 60 240 250 W Tolerance L W 3 mm H the dimensions in the order conf...

Страница 11: ...8 x ventilation hole d 7 mm C 8 x mounting hole d 7 mm3 D 2 x earthing d 2 mm A B C D 808 1000 A 4 x drainage 10 10 mm B 16 x ventilation hole 3 7 mm C 8 x mounting hole 14 9 mm3 D 2 x earthing d 2 mm...

Страница 12: ...llowing drawing for detailed information Load calculations are per formed by the system designer or installer Depending on the assembly rack the modules can be fastened to the assembly rack by means o...

Страница 13: ...e must be properly sealed to prevent the roof from leaking Caution Danger of material damage Only use the existing mounting holes in the module frame see dimensional drawing Do not carry out any indep...

Страница 14: ...the conductors size of the fuses and size of the regulating devices connected to the modules or to the system output The open circuit voltage of the PV system must not exceed the maximum permissible i...

Страница 15: ...ameters of the modules are also stated on the module type plate 4 2 Earthing Caution Danger of material damage Please observe the local regulations and provision for earthing Caution Danger of materia...

Страница 16: ...ircuit voltage Check the open circuit voltage of each strand with a digital multimeter The measured values should corre spond with the total of the open circuit voltage for the individual modules You...

Страница 17: ...module caused by a temperature increase of the solar cells or lower radia tion density 5 1 Block diodes and bypass diodes Caution Danger of electric shock Please observe the safety instructions for w...

Страница 18: ...bypass diodes If the radiation density is not very low and the volt age between the terminals deviates by more than 5 then it is probable that the port is defective 5 3 Maintenance Caution Danger of e...

Страница 19: ...high priority topic for Luxor This is why modules for disposal can be returned to Luxor for recycling Submission of the delivery note or invoice stating the date of purchase is required when returnin...

Страница 20: ...49 711 88 888 999 F 49 711 88 888 911 info luxor solar com www luxor solar com Printed on Recystar Polar a recycling paper with FSC certificate and the Blue Angel eco label klimaneutral gedruckt Zert...

Отзывы: