background image

VACUUM TUBE CONTROL AMPLIFIER

CL-38uSE

Owner`s Manual

Содержание CL-38uSE

Страница 1: ...VACUUM TUBE CONTROLAMPLIFIER CL 38uSE Owner sManual ...

Страница 2: ...Contents Precautions 1 Names and Functions 2 Connections 6 Operations 10 How to Use Remote Control 11 Block Diagram 12 Specifications 13 Before Asking for Repair Services 14 ...

Страница 3: ... inadequately connected noises including hum may be gen erated resulting in an adverse S N ratio The sound is not generated shortly after the power supply is turned on This amplifier is equipped with a time muting circuit in order to separate the output circuit Therefore no sound will be generated shortly after the pow er supply is turned on If the volume control is moved to a high sound level bef...

Страница 4: ... 5 kHz and higher can be adjusted by the tone control for treble 4 Tone defeat switch tone defeat Toggles to bypass or activate tone controls off Setting the switch to this position activates the tone controls and enables the user to adjust preferred tonal balance on Setting the switch to this position bypasses the tone control circuit At this time operating the tone control will not change the to...

Страница 5: ...se makes the right sound volume enhanced This knob shall be set to the center position under normal conditions and rotated to make adjustment if necessary 14 Mute button mute Temporarily mutes the sound Pressing this button activates the mute function and the sound volume indicator blinks No sound is generated Pressing this button again to cancel the mute function allows sound to be generated 15 C...

Страница 6: ...r Do not connect a CD player or other devices whose output level is high to this terminal Normal playback cannot be provided due to sound crack 20 Line input terminals CD LINE 1 LINE 2 LINE 3 Are used for high level signal inputs from a CD DVD player a SACD player a tuner a video deck a TV and other such devices These input terminals offer the same functions 21 Record output terminals REC OUT Are ...

Страница 7: ...ls LINE 1 LINE 2 These terminals take out the output of this unit Two lines LINE 1 and LINE 2 are provided and same signals will be output from both lines Both are always on While using one side of the line output terminals do not insert shortpin plugs to the other line output terminals No sound will be generated 24 AC inlet AC IN Connects the accessory power cable The power shall be supplied from...

Страница 8: ...6 Connections RECORDER POWER AMPLIFIER CD PLAYER CD SACD PLAYER ANALOG PLAYER ...

Страница 9: ...ion of this unit supports both the MM moving magnet type cartridge and MC moving coil type cartridge Select the position of the cartridge selector according to the type of the cartridge to be used There are low and high positions for MC Select the position of the impedance closest to the value of the cartridge to be used Cartridge selector MM MC high MC low Impedance 47 kΩ 100 Ω 30 Ω The output fr...

Страница 10: ...8 Connections RECORDER POWER AMPLIFIER CD PLAYER CD SACD PLAYER ANALOG PLAYER ...

Страница 11: ...e control functions such as the volume control and tone con trol functions Do not insert shortpin plugs into REC OUT No sound will be generated When a CD recorder tape recorder or other devices are connected be aware that the playback sound volume be comes low or no sound is generated if the device decreas es the impedance of the line input terminals of the recorder extremely or causes short circu...

Страница 12: ...control This unit has the tone control function for the low frequency and high frequency ranges The low frequency tone control bass is a function to adjust the tone range lower than the selected one with the se lector switch for low frequency The tone control is set to flat frequency characteristic at the center position Rotating the control clockwise makes the low frequency range en hanced and ro...

Страница 13: ...ed at the remote sensor R of this unit within the specified angle range shown in the illustration below 30 30 Effective distance approx 5 meters Dry cell battery How to load dry cells 1 Put your finger on the battery cover claw located behind the remote control The battery cover can be opened by sliding it downwards 2 Put 2 AAA batteries in the battery case as shown in the illustration 3 Close the...

Страница 14: ... line 2 line3 REC input selector low cut sw LED PL EQ AMP P M A L O R T N O C E N O T FLAT AMP Power Transformer LOW CUT tone defeat on BASS 100KB TREBLE 50KB frequency Hz 150 300 600Hz 1 5k 3k 6kHz ECC802S B VR LED MUTE SW WIRELESS REMOTE CONTROLLER CIRCUIT REG B RIAA MODE stereo mono mute RY MM MC H MC L phono MM MC H MC L sw MM MC H MC L monitor OUT Fuse Operation SW REG monitor CHOKE ...

Страница 15: ...50 Hz 8 0 dB at 50 Hz BASS 300 Hz 8 0 dB at 100 Hz BASS 600 Hz 8 0 dB at 200 Hz TREBLE 1 5 kHz 8 0 dB at 5 kHz TREBLE 3 kHz 8 0 dB at 10 kHz TREBLE 6 kHz 8 0 dB at 20 kHz Low cut 30 Hz 6 dB oct Input 1 phono line MM MC high MC low supported and 4 lines Recording input output 1 line for each of recording output and monitor input Output 2 Lines Supplied functions Front panel Power switch Sound volum...

Страница 16: ... clockwise to ad just the sound volume The volume is muted Cancel the MUTE mode The input selector is not set to the source position to be played back Set the input selector correctly Cable connections are incomplete Make cable connections securely The output level of the input device is set to the minimum position Adjust the output level No sound comes out from one side The connecting cable is no...

Страница 17: ...VACUUM TUBE CONTROL AMPLIFIER CL 38uSE 15 MEMO ...

Страница 18: ...16 MEMO ...

Страница 19: ......

Страница 20: ...LUXMAN CORPORATION JAPAN AG00987E53A Printed in Japan 1 3 1 Shinyokohama Kouhoku ku Yokohama shi Kanagawa 222 0033 Japan ...