9.
Ensure that all objects which may accidentally reflect the laser beam are removed from the laser
designated area. This may include personal items such as jewellery and watches.
10. Always check the condition of the laser system before beginning any work. In particular, confirm
the correct operation and condition of any safety shutters, beam delivery devices and nozzle
systems.
1.8. Training
Training of installation, operator and maintenance personnel is mandatory. Luxinar, or its authorised
distributors, can provide training on the installation, operation and maintenance of this laser
equipment.
1.9. Safety precautions
The SR AOM series incorporates various safety features as required by EN60825-1:2014 and CDRH
radiation safety standards. The system integrator is required to utilise these functions within a full
system installation to meet these safety standards.
1.9.1. Laser radiation emission warning device
To comply with relevant safety standards, installations may require a laser radiation emission warning
device to be included. Please ensure the safety functions within a system installation meet these and
any other relevant local laser safety standards. The emission warning device fitted to the laser operates
at a wavelength that is visible when wearing most laser protection goggles suitable for the laser
wavelength.
1.9.2. Safety interlocks
No sections of the laser’s protective housing can be opened without special tools. The laser has no user
serviceable parts within the protective housing and does not contain any access panel with safety
interlocks within the meaning of EN60825-1:2014 section 6.3.
1.9.3. Safety shutter
A safety shutter can be incorporated into SR AOM series lasers. The shutter prevents accidental laser
emission. It blocks or dumps the laser output beam using a reflective mechanical blade. The shutter
assembly contains sensors for monitoring the
Shutter Open
and
Shutter Closed
positions. For
details of the inputs and outputs required to operate and monitor the shutter, refer to
.
1.10. Additional system integrator safety precautions
In addition, the system integrator will also be required to add the following functions within a full
system installation to meet the CDRH, EN60825-1:2014, Machinery Directive 2006/42/EC (EN60204) and
NFPA 79 safety standards:
1.10.1. Emergency stop (E-stop) switch
It is recommended that the system integrator includes an emergency stop (E-stop) switch for the laser
to the machine control panel. This switch must be of the red mushroom type with force make/force
break contacts and approved to the relevant electrical standards.
1.10.2. Power on/off key switch
It is also recommended that the system integrator adds the facility for a power on/off key switch, such
that the system can be switched off and the key removed when the laser is not in operation.
1.10.3. Manual restart
It is a statutory requirement of 21 CFR 1040.10 and EN60825-1:2014 that the laser output should not be
restored automatically if the mains power fails or an interlock is broken and then reset. The system
integrator must provide for a manual restart mechanism under these circumstances.
1. Safety
6
906-0227-00 REV 1
Содержание SR 10 AOM
Страница 1: ...USER MANUAL SR AOM series Sealed CO2 laser sources with integrated AOM...
Страница 8: ...Preface iv 906 0227 00 REV 1...
Страница 40: ...6 Installation 32 906 0227 00 REV 1...
Страница 42: ...7 Transport and recommissioning 34 906 0227 00 REV 1...
Страница 52: ...8 Interfacing 44 906 0227 00 REV 1...
Страница 54: ...A Dimensional drawings 46 906 0227 00 REV 1...