4. Secure the mounting brackets to the wall
with the screws.
5. Apply thread sealant tape to the threading
on the shut off valves before connect both hot
and cold water supply hoses to the valves.
IMPORTANT :
- Make sure the water supply hoses are
connected to the corresponding valves - i.e.
cold water hose to the cold water valve and
the same for hot water hose. The mixing valve
will not function properly if the hoses are
installed incorrectly.
- Before hanging the shower panel on the
wall. Turn on both valves and test all functions
on the shower panel and check for leaks at
this point. You should have good water flow to
the shower panel and full temperature control
from the knobs.