Luxier BSH05-S Скачать руководство пользователя страница 4

4

BSH05S Rev. B 07/2018

Luxier USA

Installation

B

C

A. Shut off water supply at the valves. 

Remove old faucet and clean the 

mounting surface for installation of new 

faucet.

D1. Apply Teflon (TPFE) tape on the 

shut off valves. Thread the tape in 

counter-clockwise direction.

F. Remove aerator from the spout and 

let the water run for about 1 minute to 

clear any debris in the plumbing system.

Attach the aerator.

D2. Use a wrench to tighten the hoses, 

please do not overtighten the connec-

tions.

E. Turn on the water supply to check for 

leaks at all connections.

B. First place the new faucet through 

flange on the mounting surface. The 

faucet hole should be 1 3/8” in diameter 

on the mounting surface.

C. Insert the plastic washer, metal 

washer, and secure the faucet with the 

mounting nut.

D1

Flexible water supply line

D2

E

F

A

01

02

03

04
05

06

07

08

09

10
11

12

13
14
15

01. Plug

02. Setscrew

03. Handle

04. Cap

05. Bonnet

06. Cartridge

07. Body

08. Aerator

09. Water Supply Hoses

10. Base

11. Screws

12. Rubber Washer

13. Rubber Gasket

14. Metal Washer

15. Locking Nut

Содержание BSH05-S

Страница 1: ...ss Construction Single Hole Installation Drip Free Ceramic Cartridge NEOPERL aerator 1 2 gpm maximum at 60 psi Complies with NSF 61 9 ASME A112 18 1 CSA B125 1 IAPMO UPC cUPC CA AB 1953 ADA Max Deck Thickness 2 3 8 compression fitting Drawing not to Scale All Measurements are Approximate Approx 30 water supply hose 3 5 5 1 56 1 81 11 69 2 875 5 5 3 1 3 8 Hole Size ...

Страница 2: ...igence improper installation product abuse product misuse or use of cleaners containing abrasives alcohol or other organic solvents whether per formed by a contractor service company or yourself are excluded from this warranty Our responsibility under this warranty is limited to only to replacement parts and no other costs Luxier USA will not be responsible for labor charges and or damage incurred...

Страница 3: ...the compression nuts as it will reduce the integrity of the sealed connection You may also need the following tools 1 Safety Glasses 5 Adjustable Wrench 2 Teflon TPFE Tape 6 Screwdriver 3 Plumber s Putty and Caulking 4 1 3 8 Basin Wrench or 1 11 32 Shower Valve Socket Wrench Maintenance Guide Please follow the cleaning material manufacturer s instructions Damage caused by improper treatment will n...

Страница 4: ...to tighten the hoses please do not overtighten the connec tions E Turn on the water supply to check for leaks at all connections B First place the new faucet through flange on the mounting surface The faucet hole should be 1 3 8 in diameter on the mounting surface C Insert the plastic washer metal washer and secure the faucet with the mounting nut D1 Flexible water supply line D2 E F A 01 02 03 04...

Отзывы: