Luxibel LX119 Скачать руководство пользователя страница 9

 

LX119 

V. 01 – 19/06/2014 

©Velleman nv 

10 

000 

10 

no function 

011 

60 

auto programme 1 

061 

120 

auto programme 2 

121 

180 

auto programme 3 

181 

240 

auto programme 4 

241 

255 

auto programme 0 (auto 1-4) 

11 

000 

255 

auto speed slow-fast 

12 

000 

51 

preset dimmer speed from control panel 

052 

101 

dimmer speed mode off 

102 

152 

dimmer speed mode 1 (fast) 

153 

203 

dimmer speed mode 2 (middle) 

204 

255 

dimmer speed mode 3 (slow) 

 

7.11

 

White Balance 

Enter this option to adjust the white balance. 

1.

 

Press MENU until <WHITE BALANCE> appears on the display. Press ENTER to confirm. 

2.

 

Select the colour (R, G or B) with UP or DOWN and press ENTER to confirm. 

3.

 

Set the value (000-255) with UP or DOWN. Press ENTER to save the setting. 

4.

 

Press MENU to go back. 

7.12

 

Fixture Settings and Information 

Dimmer 

Selection of the dimming curve. 

1.

 

Press MENU until <DIM MODE> appears on the display. Press ENTER to confirm. 

2.

 

Select the dimming curve (off, DIM1, DIM2 or DIM3) with UP or DOWN and press ENTER to confirm. 

3.

 

Press MENU to go back. 

BackLite 

Activation of the display backlight. 

1.

 

Press MENU until <BACKLITE> appears on the display. Press ENTER to confirm. 

2.

 

Select the activation time (on, 10s, 20s or 30s) with UP or DOWN and press ENTER to confirm. 

3.

 

Press MENU to go back. 

Auto Test 

Start the automatic test function to check if the device is working properly. 

1.

 

Press MENU until <INFO> appears on the display. Press ENTER to confirm. 

2.

 

Select <AUTO> with UP or DOWN. 

3.

 

Press ENTER to confirm and to start the automatic testing. 

FixHours 

Shows the device’s working hours. 

1.

 

Press MENU until <INFO> appears on the display. Press ENTER to confirm. 

2.

 

Select <FIXHOURS> with UP or DOWN and press ENTER to confirm. 

3.

 

Press MENU to go back. 

Version 

Shows the device’s firmware version. 

1.

 

Press MENU until <INFO> appears on the display. Press ENTER to confirm. 

2.

 

Select <VERSION> with UP or DOWN and press ENTER to confirm. 

3.

 

Press MENU to go back. 

Temp 

Shows the device’s working temperature. 

1.

 

Press MENU until <TEMP> appears on the display. Press ENTER to confirm. 

2.

 

Press MENU to go back. 

Содержание LX119

Страница 1: ...LX119 SMART HEXA LED PAR 12 X 12 W RGBWAP LED USER MANUAL...

Страница 2: ...LX119 V 01 19 06 2014 2 Velleman nv...

Страница 3: ...ice Keep this device away from children and unauthorized users Caution device heats up during use Do not stare directly at the light source as this may cause epileptic seizure in sensitive people temp...

Страница 4: ...ent of 240 VAC 50 Hz Lighting effects are not designed for permanent operation regular operation breaks will prolong their lives Use the original packaging if the device is to be transported Keep this...

Страница 5: ...urrent does not exceed the power line s nominal current Use power cables with an adequate section The installation has to be approved by an expert before the device is taken into service DMX 512 Conne...

Страница 6: ...the master or slave unit select MASTER or SLAVE with UP or DOWN and press ENTER to confirm 3 Select the desired programme see 7 3 Auto Mode 4 Use standard DMX cables to daisy chain your units together...

Страница 7: ...controller not incl and the other side to the male XLR input 3 or 4 of the device Multiple devices can be linked through serial linking The linking cable shall be a dual core screened cable with XLR i...

Страница 8: ...000 255 amber 0 100 6 000 255 white 0 100 7 000 255 purple 0 100 8 000 10 no function 011 255 strobe slow fast 9 000 10 no function 011 30 red 100 green 0 100 blue 0 031 50 red 100 0 green 100 blue 0...

Страница 9: ...IM1 DIM2 or DIM3 with UP or DOWN and press ENTER to confirm 3 Press MENU to go back BackLite Activation of the display backlight 1 Press MENU until BACKLITE appears on the display Press ENTER to confi...

Страница 10: ...use by a fuse of the same type and rating 1 Before replacing the fuse unplug the mains lead 2 Unscrew the fuse holder 12 with an appropriate screwdriver 3 Remove the old fuse and install the new fuse...

Страница 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...

Отзывы: