Unitary Products Group

and drain all condensate. Less collection of stagnate 
condensate will build-up. The condensate pan conforms 
to ASHRAE 62-89 standards (Ventilation for Acceptable 
Indoor Air Quality).

Condensate Drain

 - The heavy duty, 3/4 inch NPTI 

copper connection is more durable over time. The 
connection is rigidly mounted to assure proper fit and leak 
tight seal.

Durable Finish

 - With a heavy duty cabinet made of pre-

painted, galvanized steel the neutral color blends into 
surrounding areas. The pre-paint provides a better paint 
to steel bond, which resists corrosion and rust creep, 
insures less fading when exposed to sunlight and offers a 
more attractive on site appearance.

Full Perimeter Base Rails

 - The base rails provide a 

solid foundation for the entire unit and protects the unit 
during shipment. The rails provide fork lift access from all 
sides. On applications where the unit is placed on a pad, 
the base will keep the unit off the pad to deter corrosion.

More Attractive Appearance

 - A single piece Water 

Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation 
and provides a wider variety of installations. The one 
piece design adds greater water integrity.

Top Discharge

 - The top discharge condenser fan does 

not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted 
fan is blown up away from the structure and any 
landscaping. This allows compact location on multi-unit 
applications.

Condenser Coil Guard

 - A multi-piece totally enclosed, 

rigidly mounted condenser coil guard provides protection 
from objects after installation and provides protection 
during transit.

Low Operating Sound Level

 - The upward air flow 

carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds.

Fan System

 - All models operate over a wide range of 

design conditions with a constant torque fan motor. These 
units have 5 speed taps to provide greater on site flexibility 
to match comfort requirements.

Protected Compressor

 - The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which protect 
the compressor if undesirable operating conditions occur.

Pressure Switches 

- High pressure switches standard in 

all heat pump units. When abnormal conditions are 
sensed through the pressure switches, the unit will lock 
out after 3 tries preventing any further operation until reset 
or problem is corrected. 

Exclusive Coil Design

 - Grooved copper tubes and 

enhanced aluminum fin construction improves heat 
transfer for maximum efficiency and durability.

Low Maintenance

 - Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit.

Secured Service Access Ports

 - Protected, externally 

mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.

Easy Service Access

 - A large, single panel covers the 

electrical controls makes servicing easy. The blower 
compartment has a large panel which when removed will 
allow the blower fan assembly to slide-out for ease of  
maintenance and trouble shooting.

Replacement Parts

 - The installer requires no special 

training to replace any of the components of these units 
and does not need to maintain an inventory of unique 
parts.

Field Installed Accessories

Wall Thermostat

 - The units are designed to operate with 

24-volt electronic and electro-mechanical thermostats.

Electric Heat Kit

 - Available in 3 different kW capacities 

(5, 10 and 15 kW). (Single phase only)

Start Assist Kits

 - Available for all models.

Outdoor Thermostat

 - Available for all heat pump models.

Guide Specifications

GENERAL

Units shall be factory-assembled, single packaged, Electric 
Cooling units, designed for outdoor mounted installation. Units 
shall have minimum SEER ratings of 13.0. Heat pump 7.7 HSPF.

The units shall be factory wired, piped, charged with R-22 
refrigerant and factory tested prior to shipment. All unit wiring 
shall be color coded.

All units shall be manufactured in a facility certified to ISO 9001 
standards, and the cooling performance shall be rated in 
accordance with DOE and ARI test procedures. Units shall be 
certified to UL 1995/CAN/CSA C22.2 No. 236 standards.

UNIT CABINET

1.

Unit cabinet shall be constructed of G90, pre-paint textured 
steel, certified at 500 hours salt spray test per ASTMB117 
standards.

2.

The unit top shall be a single piece "Water Shed" design.

3.

Unit shall have a rigidly mounted condenser coil guard to 
provide protection from objects and personnel after 
installation.

4.

Indoor blower section shall be insulated with up to 3/4" 
thick insulation.

5.

Cabinet panels shall be "large" size, easily removable for 
servicing and maintenance.

Содержание Climasure PAC024

Страница 1: ...ng air conditioners are designed for outdoor installation Only utility and duct connections are required at the point of installation Field installed electric heater accessories are available to provi...

Страница 2: ...Sound Performance 27 Electrical Data 27 Weights and Dimensions 35 Component Location Cooling Unit and Heat Pump LUHFW ULYH RQGHQVHU DQ 0RWRU HFRUDWLYH 3URWHFWLYH RLO XDUG HDY DXJH DVH 5DLOV RQWURO R...

Страница 3: ...nd gas system safeties are monitored and recorded by the system to insure unit performance Equal size side supply and return duct connections allows easy hook up of ducts to match low crawl spaces wit...

Страница 4: ...mpressor if undesirable operating conditions occur Pressure Switches High pressure switches standard in all heat pump units When abnormal conditions are sensed through the pressure switches the unit w...

Страница 5: ...unting Coils a Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed b Evaporator and Condenser coils sh...

Страница 6: ...11 3 16 0 16 0 Rows 2 2 2 2 2 2 Fins per inch 15 15 15 15 15 15 Tube diameter in 3 8 3 8 3 8 3 8 3 8 3 8 Circuitry Type Intertwined Intertwined Intertwined Intertwined Intertwined Intertwined EVAPORAT...

Страница 7: ...ecip Recip Recip Recip Scroll Scroll Quantity 1 1 1 1 1 1 CONDENSER COIL DATA Face area Sq Ft 11 28 11 28 11 28 16 16 16 Rows 2 2 2 2 2 2 Fins per inch 15 15 15 15 15 15 Tube diameter in 3 8 3 8 3 8 3...

Страница 8: ...024 2 0 PAC PHP 208 230 1 60 187 252 125 030 2 5 PAC PHP 208 230 1 60 187 252 125 036 3 0 PAC PHP 208 230 1 60 187 252 125 208 230 3 60 187 252 125 042 3 5 PAC PHP 208 230 1 60 187 252 125 048 4 0 PA...

Страница 9: ...0 9 8 8 21 7 1 9 16 0 14 0 12 0 10 0 7 9 67 23 1 1 8 20 5 18 5 16 5 14 4 12 4 10 4 8 4 19 8 1 9 18 5 17 2 15 4 13 4 11 4 9 3 7 3 62 21 7 1 8 21 7 21 0 19 6 17 6 15 6 13 5 11 5 18 7 1 9 18 7 18 4 18 0...

Страница 10: ...9 4 67 27 4 2 2 25 0 22 5 19 9 17 4 14 9 12 3 9 8 24 3 2 5 23 0 21 1 18 6 16 1 13 6 11 0 8 5 62 25 7 2 2 25 7 25 3 23 9 21 4 18 8 16 3 13 8 23 0 2 5 23 0 22 8 21 8 19 3 16 8 14 2 11 7 57 25 7 2 2 25 7...

Страница 11: ...4 24 3 21 3 18 3 15 3 12 2 31 9 3 0 28 7 26 1 23 1 20 1 17 0 14 0 11 0 62 33 7 2 7 33 4 32 1 29 4 26 4 23 3 20 3 17 3 30 4 3 0 30 3 29 5 27 4 24 4 21 4 18 3 15 3 57 33 7 2 7 33 4 32 1 29 4 26 4 23 3...

Страница 12: ...0 28 4 24 9 21 4 17 8 14 3 36 7 3 4 33 1 29 9 26 4 22 8 19 3 15 8 12 2 62 38 6 3 1 38 5 37 0 34 1 30 6 27 0 23 5 20 0 34 9 3 3 34 9 33 7 31 0 27 5 24 0 20 4 16 9 57 38 6 3 1 38 5 37 0 34 1 30 6 27 0...

Страница 13: ...8 26 7 22 7 18 7 14 6 42 0 3 7 37 1 33 2 29 1 25 1 21 1 17 0 13 0 62 44 1 3 4 43 0 41 0 36 9 32 9 28 8 24 8 20 8 40 4 3 7 39 8 37 9 34 1 30 1 26 0 22 0 17 9 57 44 1 3 4 43 0 41 0 36 9 32 9 28 8 24 8...

Страница 14: ...35 9 30 8 25 7 20 7 15 6 54 8 4 6 45 8 40 8 35 7 30 7 25 6 20 6 15 5 62 66 1 4 3 33 0 27 9 22 9 17 8 12 8 7 7 2 7 57 5 4 6 40 5 36 8 31 7 26 7 21 6 16 6 11 5 57 59 4 4 1 46 0 40 9 35 9 30 8 25 7 20 7...

Страница 15: ...13 1 11 1 9 0 67 24 5 1 9 22 0 19 9 17 9 15 9 13 9 11 9 9 8 21 6 2 0 20 3 18 9 17 0 15 0 12 9 10 9 8 9 62 23 3 1 9 23 3 22 7 21 5 19 5 17 5 15 4 13 4 20 9 2 0 20 9 20 6 19 9 17 9 15 8 13 8 11 8 57 23...

Страница 16: ...17 5 15 0 12 5 9 9 7 4 67 25 4 2 0 22 2 19 7 17 2 14 7 12 1 9 6 7 1 22 8 2 2 20 7 18 6 16 0 13 5 11 0 8 5 5 9 62 26 0 2 1 25 2 23 6 21 1 18 5 16 0 13 5 11 0 23 1 2 2 22 7 21 4 19 0 16 5 14 0 11 4 8 9...

Страница 17: ...24 5 21 4 18 4 15 4 12 3 31 2 3 2 28 7 26 3 23 3 20 3 17 2 14 2 11 2 62 33 4 2 9 32 8 31 3 28 2 25 2 22 2 19 1 16 1 30 1 3 1 29 8 28 8 26 4 23 4 20 4 17 3 14 3 57 33 4 2 9 32 8 31 3 28 2 25 2 22 2 19...

Страница 18: ...26 9 23 3 19 8 16 2 39 9 3 6 35 6 32 4 28 9 25 3 21 8 18 3 14 7 62 42 3 3 3 41 1 38 6 35 1 31 6 28 0 24 5 20 9 39 3 3 6 38 2 36 2 32 7 29 1 25 6 22 1 18 5 57 42 3 3 3 41 1 38 6 35 1 31 6 28 0 24 5 20...

Страница 19: ...29 5 25 4 21 4 17 4 45 2 4 1 40 3 36 6 32 5 28 5 24 4 20 4 16 4 62 46 9 3 5 44 5 41 4 37 4 33 3 29 3 25 2 21 2 45 4 4 1 42 8 39 9 35 9 31 8 27 8 23 7 19 7 57 46 9 3 5 44 5 41 4 37 4 33 3 29 3 25 2 21...

Страница 20: ...6 36 6 31 5 26 5 21 4 52 5 4 9 47 8 44 1 39 0 34 0 28 9 23 9 18 8 62 63 6 4 5 55 0 50 0 44 9 39 8 34 8 29 7 24 7 54 5 5 0 49 4 45 7 40 6 35 6 30 5 25 5 20 4 57 63 6 4 5 55 0 50 0 44 9 39 8 34 8 29 7...

Страница 21: ...66 1 76 1 86 1 97 2 07 2 17 2 27 2 37 1000 55 MBH 10 56 12 31 14 45 17 07 20 27 24 17 28 94 34 76 KW 1 30 1 40 1 50 1 60 1 70 1 80 1 91 2 01 70 MBH 7 93 9 69 11 83 14 45 17 65 21 55 26 32 32 14 KW 1...

Страница 22: ...03 3 17 3 30 70 MBH 16 15 19 13 22 65 26 83 31 77 37 62 44 56 52 77 KW 2 94 3 08 3 21 3 34 3 48 3 61 3 75 3 88 80 MBH 14 15 17 13 20 65 24 82 29 77 35 62 42 56 50 77 KW 3 23 3 36 3 50 3 63 3 76 3 90...

Страница 23: ...4 236 910 878 251 980 821 269 1053 751 281 1125 Medium 1166 306 912 1101 323 977 1037 338 1042 977 351 1102 833 321 1139 Medium High 1255 385 971 1169 400 1030 1109 412 1087 996 384 1123 841 328 1146...

Страница 24: ...0 09 700 0 08 0 08 0 08 0 09 0 10 800 0 09 0 09 0 09 0 10 0 12 900 0 1 0 10 0 10 0 11 0 13 1000 0 12 0 12 0 12 0 13 0 15 1100 0 13 0 13 0 13 0 14 0 17 1200 0 15 0 15 0 15 0 16 0 19 1300 0 17 0 17 0 17...

Страница 25: ...0 38 0 41 2100 0 39 0 39 0 39 0 40 0 43 2200 0 41 0 41 0 41 0 42 0 45 060 5 0 PAC 800 0 09 0 09 0 09 0 10 0 12 900 0 1 0 10 0 10 0 11 0 13 1000 0 12 0 12 0 12 0 13 0 15 1100 0 13 0 13 0 13 0 14 0 17 1...

Страница 26: ...0 1160 PHP 1300 1300 1270 1270 060 5 0 PAC 208 230 1 60 1300 1300 1270 1160 PHP 1300 1300 1270 1270 Indoor Blower Specifications Size Tons Model Motor HP RPM Eff SF Frame 024 2 0 PAC PHP 1 2 1100 0 8...

Страница 27: ...1 7 59 7 69 8 79 8 70 80 030 2 5 208 230 1 60 10 6 61 0 16 5 1 1 4 1 None 19 8 25 2PH08510506 3 6 4 8 1 17 2 19 9 26 7 30 0 30 30 2PH08510706 4 9 6 5 1 23 5 27 1 34 5 39 0 35 40 2PH08511006 7 2 9 6 1...

Страница 28: ...19 9 44 0 47 3 50 50 2PH08510706 4 9 6 5 1 23 5 27 1 51 8 56 3 60 60 2PH08511006 7 2 9 6 1 34 5 39 8 65 6 72 2 70 80 2PH08511506 10 8 14 3 1 51 7 59 7 87 1 97 1 90 100 208 230 3 60 8 2 72 0 16 0 1 6...

Страница 29: ...246836 LTG E 0107 Unitary Products Group 29 PAC PHP024 060 Typical Wiring Diagrams PAC024 060 Typical Cooling Unit 208 230 1 60 volt Wiring Diagram...

Страница 30: ...246836 LTG E 0107 30 Unitary Products Group PAC036 048 and 060 Typical Cooling Unit 208 230 3 60 volt Wiring Diagram...

Страница 31: ...246836 LTG E 0107 Unitary Products Group 31 PAC048 060 Typical Cooling Unit 460 3 60 volt Wiring Diagram...

Страница 32: ...246836 LTG E 0107 32 Unitary Products Group PHP024 060 Typical Heat Pump 208 230 1 60 volt Wiring Diagram...

Страница 33: ...246836 LTG E 0107 Unitary Products Group 33 PHP036 048 and 060 Typical Heat Pump 208 230 3 60 volt Wiring Diagram...

Страница 34: ...246836 LTG E 0107 34 Unitary Products Group PHP060 Typical Heat Pump 460 3 60 volt Wiring Diagram...

Страница 35: ...9 70 PHP 345 342 21 75 14 79 71 91 101 030 2 5 PAC 273 270 21 75 14 63 62 71 73 PHP 350 347 21 75 14 80 72 92 103 036 3 0 PAC 348 345 23 5 15 79 83 94 90 PHP 353 350 23 5 15 80 84 95 91 042 3 5 PAC 35...

Страница 36: ...3 16 30 11 16 47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 PHP 32 13 16 30 11 16 47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 042 3 5 PAC 32 13 16 30 11 16 47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 PHP 32 13 16 34 11 1...

Страница 37: ...n Distance in Direction Distance in Top1 1 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 60 Right 24 Front 36 Left 24 Rear2 2 Unit...

Страница 38: ...246836 LTG E 0107 38 Unitary Products Group...

Страница 39: ...246836 LTG E 0107 Unitary Products Group 39...

Страница 40: ...t to change without notice Printed in U S A 246836 LTG E 0107 Copyright 2007 by Unitary Products Group All rights reserved Supersedes 246836 LTG D 1206 Unitary 5005 Norman Products York OK Group Drive...

Отзывы: