567177-LTG-D-1211
Johnson Controls Unitary Products
7
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
FURNACE
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
WIDTH
RATED
CFM
NET MBH
SEER
1,2
EER
TOTAL
SENS.
AL6B024F3(C)
600 - 1000
14
FC/MC/PC32
800
23.6
17.0
14.50
12.25
600 - 1000
17,21
FC/MC/PC35
800
23.6
17.0
14.50
12.25
600 - 1000
14
FC/MC/PC37
800
24.0
17.3
14.50
12.25
600 - 1000
17,21
FC/MC/PC43
800
24.0
17.3
14.50
12.25
AL6B030F3(C)
800 - 1200
14
FC/MC/PC32
1000
29.6
20.6
14.00
12.00
800 - 1200
17,21
FC/MC/PC35
1000
29.6
20.6
14.00
12.00
800 - 1200
14
FC/MC/PC37
1000
30.0
21.0
14.25
12.25
800 - 1200
17,21
FC/MC/PC43
1000
30.0
21.0
14.25
12.25
800 - 1200
21,24
FC/MC/PC48
1000
30.0
21.4
14.25
12.25
800 - 1200
21,24
FC/MC/PC60
1000
30.0
21.2
14.25
12.25
800 - 1200
21,24
UC48
1000
28.6
20.0
13.75
11.75
800 - 1200
21,24
UC60
1000
28.8
19.9
13.75
11.75
AL6B036F3(C)
1000 - 1400
14
FC/MC/PC37
1200
35.0
26.0
14.00
12.25
1000 - 1400
17,21
FC/MC/PC43
1200
35.0
26.0
14.00
12.25
1000 - 1400
21,24
FC/MC/PC48
1200
35.0
26.0
14.00
12.25
1000 - 1400
21,24
FC/MC/PC60
1200
35.0
26.0
14.00
12.25
1000 - 1400
24
FC/MC62
1200
35.4
26.0
14.00
12.25
1000 - 1400
24
FC64
1200
36.4
27.4
14.50
12.50
1000 - 1400
–
HD48
1200
35.0
25.8
14.00
12.25
1000 - 1400
–
HD60
1200
35.4
26.0
14.00
12.25
1000 - 1400
21,24
UC48
1200
34.6
25.8
13.75
12.00
1000 - 1400
21,24
UC60
1200
34.6
25.4
13.75
12.00
AL6B042F3(C)
1200 - 1600
21,24
FC/MC/PC60
1400
41.5
30.2
14.25
12.00
1200 - 1600
24
FC/MC62
1400
41.5
30.2
14.50
12.25
1200 - 1600
24
FC64
1400
42.5
31.8
15.00
12.50
1200 - 1600
–
HD60
1400
42.0
30.8
14.25
12.25
1200 - 1600
21,24
UC60
1400
40.5
29.6
13.75
11.75
AL6B048F3(C)
1400 - 1800
21,24
FC/MC/PC48
1600
45.0
32.2
13.75
12.00
1400 - 1800
21,24
FC/MC/PC60
1600
45.0
32.2
13.75
12.00
1400 - 1800
24
FC/MC62
1600
45.5
32.8
13.75
12.00
1400 - 1800
24
FC64
1600
47.0
34.2
14.25
12.50
1400 - 1800
–
HD48
1600
45.0
32.2
13.75
12.00
1400 - 1800
–
HD60
1600
46.0
32.8
14.00
12.25
AL6B060F3(C)
1500 - 1900
24
FC64
1800
53.5
37.4
14.50
12.50
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
2. TXV = Use S1-1TVM series kit.