Luxair LA-350 Скачать руководство пользователя страница 2

INSTRUCTIONS FOR USE and PRECAUTIONS 

Before the fist use pay attention to what has been written in the attached manual. 

This appliance should not be operated by minors,
children under the age of eight years old or people
with learning difficulties, Children above eight years
old must be supervised and given clear instruction
as to the operation of this appliance. Children shall
not play with the appliance.
Cleaning and maintenance should only be carried out
by a competent person under the strict supervision
of an adult. Never use abrasive cleaning materials on
the appliance.

Before any cleaning or maintenance operation, disconnect the appliance from the
main supply, by means of the main switch or the bipolar switch.

If other gas equipment or equipment which consumes oxygen from the environment is
used, ventilation must be sufficient. For safe ventilation, maximum depression in the
room should not exceed 4 Pa (0,04 mbar) and there must be a hole on the outside
facing wall (suitably positioned and dimensioned). If in doubt, national and
international standards precisely indicate the rules for the state of art installation of
gas systems and for environment air change, to avoid the possibility of incomplete
combustions with the risk of poisonous fumes being emitted.

Keep the grease filters clean, taking into account the recommended cleaning
suggestions.

Do not use the appliance to suction gas, fumes, vapours or other substances different
from the normal fumes from the inside environment.

The appliance is not suitable to aspirate liquids.

Do not direct jets of water toward the appliance.

GENERAL

 

In the SUCTION use extracts air, fumes and vapours from the inside environment and 
then expels them outside. It is not necessary to use carbon filters for purifying. 

BEFORE MOUNTING

 

The instruction manual apply to several versions of the appliance. Accordingly you may find 
descriptions of individual features that do not apply to your specific appliance. 

Arrange for a socket outlet or standard connection to the electric mains; it is necessary to 
make a hole towards the outside (i.e in the open air) for the scavenging of the fumes. 

Содержание LA-350

Страница 1: ...Instruction manual LA 350 650 950 Small Ceiling Hood...

Страница 2: ...acing wall suitably positioned and dimensioned If in doubt national and international standards precisely indicate the rules for the state of art installation of gas systems and for environment air ch...

Страница 3: ...nce always wear protective handgloves to prevent injuries DISMANTLING AND REPOSITIONING OF THE FILTERS Switch the light off and wait untill the bulbs are completely cooled down Follow the steps as sho...

Страница 4: ...h the transformer unit supplied with the appliance and must be connected only to a very safety low tension corresponding to the marking on the appliance Wiring diagramm Connect the wires of the second...

Страница 5: ...if it is wished to install the transformer unit with a plug it is necessary that you have access to the plug always turn off the main voltage supply by means of the bipolar switch before connecting an...

Страница 6: ...10 minutes the motor reduces the speeds in automatic way If you press this push button it reduces the speeds until the lowest speed is raached If you press this push button it stops the motor If you...

Страница 7: ...ilters are very dirty the motor can only take in a small quantity of air and performance is reduced CLEANING To preserve the apliance in good condition clean this periodically following the advice giv...

Страница 8: ...ronic Equipment WEEE This norm is the frame of a European wide validity of return and recycling of Waste Electrical and Electronic Equipment The symbol on the product or on its packaging indicates tha...

Страница 9: ...M 2 M 1 120 120 1 120 200 150 180 180 X kg 50 SHOWAIR 300 SHOWAIR 600 SHOWAIR 900 X 335 550 650 Model...

Страница 10: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m A 220 240 Vac TRAFO 12Vdc OK NO M 3...

Страница 11: ...2 25 m 0 15 m 2 25 m 0 15 m 0 6 m 0 6 m 0 6 m 2 25 m 1 2 m 1 2 m 1 2 m B C M 3...

Страница 12: ...M 5 M 4 2 12 Vdc PL PM PS 3 4 5 6 OPTIONAL...

Страница 13: ...M 7 M 6 9 8 7 10 12 11 10 12 12 12...

Страница 14: ...M 8...

Страница 15: ...the remote control please ask a qualified electrician for advise or simply order the switch unit direct for Luxair see spares section on our website Your ceiling extractor is already pre wired to the...

Страница 16: ...ting it at you extractor 3 whilst keeping your finger on the button now turn the power back on to your fan keep the pressed all the time you will hear a BEEP to confirm the unit has accepted the code...

Страница 17: ...ith Luxair within 21 days of installation either or by mail A 12 month parts and labour warranty is standard without product registration but proof of purchase may be required Please note the 2 years...

Отзывы: