On the thermostat’s circuit board, there is a row of DIP switches, labeled #1
through #8.  The position of these switches will change how the thermostat
operates, and also how information is conveyed to you on the LCD display
screen.  If you make any changes to these options, the changes are not
recognized unless you either: change the position of the HEAT/OFF/COOL
mode switch, or press the “HW RST” (Hardware Reset) button on the circuit
board.  The use of this button is further
described in the “ADVANCED FEATURES”
section of this manual.

These option switches are very small and
should be moved carefully using objects
such as: eyeglass screwdriver, fine-point
pen, toothpick, or similar.  The listing
below describes the available choices for
each option switch:

SWITCH #1 (SYSTEM):

[OFF/RIGHT = FURN, default] This setting is used for

the majority of all heating systems that are not heat pumps.  Examples for
this setting would be: natural gas furnace, hot water baseboard heat, and oil
heat.  [ON/LEFT = HP] Use this setting if you have a heat pump unit (which
looks just like an outside air conditioning unit, but is used for both cooing
and heating).

SWITCH #2 (TYPE):

[OFF/RIGHT = PROG, default] The thermostat controls

the room temperature by following temperature program periods that you set
up based upon your daily routine.  [ON/LEFT = MAN] The thermostat
operates manually just like a mechanical or non-programmable model.  This
method of operation is very basic and only shows the room temperature and
set temperature; there are no temperature programs, days of the week, or
clock times.

SWITCH #3 (PERIODS):

[OFF/RIGHT = 4, default] The thermostat uses four

temperature program periods in both heating and cooling (MORN, DAY, EVE,
and NITE).  Each period has a separate start time and a set temperature.
[ON/LEFT = 2] The thermostat operates in the same manner as above,
however there are only two temperature program periods for heating and
cooling (DAY and NITE).  This may be more convenient if you are typically
home during the day, and only need the set temperature to be different while
you are sleeping.

17

ON

12345678

HARDWARE SETUP OPTIONS:

Содержание TX9600TS

Страница 1: ...OGRAMMABLE TOUCHSCREEN THERMOSTAT FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT Please read all of these instructions carefully before beginning install...

Страница 2: ...mbined load of 3 0A for all terminals combined COMPATIBLE WITH Most 24 volt heating and cooling systems 1 or 2 stage Heat 1 stage Cool Gas Oil or Electric systems 1 or 2 stage Heat 1 stage Cool Heat P...

Страница 3: ...r unauthorized users Manual temperature hold Adjustable vacation hold 1 to 30 days Temporary temperature override Adjustable temperature differential cycle rate Adjustable 2nd heat stage Offset settin...

Страница 4: ...or construction work is still ongoing cover the thermostat completely or wait until this work is complete before installation WARNING All wiring must conform to the local codes and ordinances that are...

Страница 5: ...ll Try to line up the screw holes from the prior thermostat and install the mounting screws 4 If the previous holes cannot be used hold the thermostat base against the wall so that it appears straight...

Страница 6: ...t of a family of similar models that have the same general visual appearance Even though this base plate may look the same as base plates from other models the wiring connections may have different te...

Страница 7: ...tem using the System Common wire This can be used alone or in addition to installing batteries as a backup NOTE connecting the System Common wire to the thermostat is not necessary for heating and coo...

Страница 8: ...NTIONAL HEATING AND COOLING 11 1 STAGE HEAT 4 5 WIRES 5 CONVENTIONAL HEATING AND COOLING 12 2 STAGE HEAT 5 6 WIRES 6 CONVENTIONAL HEATING AND COOLING 13 TWO TRANSFORMERS 5 6 WIRES 7 HEAT PUMP HEATING...

Страница 9: ...LLIVOLT 2 WIRE HEAT USE RH W1 Factory RH RC Jumper Wire Installed 1 2 3 4 5 WIRES C HEATER STAGE 2 STAGE 1 FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON FAN WIRE MAY NOT BE PRESENT IN ALL SYSTEMS NOTE THE...

Страница 10: ...ITH A 3 WIRE ZONE VALVE Factory RH RC Jumper Wire Installed 2 3 4 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC SYSTEM 24V TRANSFORMER SYSTEM COMMON OPEN H...

Страница 11: ...RC RH 1 STAGE COOLING ONLY Factory RH RC Jumper Wire Installed 3 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON 3 4 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECI...

Страница 12: ...N HEAT PUMP 1 STAGE HEATING AND 1 STAGE COOLING Factory RH RC Jumper Wire Installed 4 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON HEATER AIR CONDITIONER 4 5 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TY...

Страница 13: ...PUMP 2 STAGE HEATING AND 1 STAGE COOLING Factory RH RC Jumper Wire Installed 5 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON AIR CONDITIONER 5 6 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TER...

Страница 14: ...STAGE COOLING WITH TWO SEPARATE 24V TRANSFORMERS Factory RH RC Jumper Wire REMOVED 6 FAN HEAT 24V TRANSFORMER COOL 24V TRANSFORMER SYSTEM COMMON HEATER AIR CONDITIONER 5 6 WIRES NOTE THE BLACK TERMIN...

Страница 15: ...ENCY HEAT 7 C SYSTEM 24V TRANSFORMER SYSTEM COMMON 4 5 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC O P T I O N A L HEAT PUMP REVERSING VALVE Use O or B T...

Страница 16: ...EAT PUMP SYSTEM WITH AUX AND EMERGENCY HEAT Factory RH RC Jumper Wire Installed 8 SYSTEM 24V TRANSFORMER SYSTEM COMMON 5 6 WIRES NOTE THE BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE B...

Страница 17: ...ard heat and oil heat ON LEFT HP Use this setting if you have a heat pump unit which looks just like an outside air conditioning unit but is used for both cooing and heating SWITCH 2 TYPE OFF RIGHT PR...

Страница 18: ...the 2 minute setting SWITCH 7 RECOVERY OFF RIGHT DISABLE default The Early Recovery feature affects how the thermostat transitions from an energy saving setback DAY and NITE program period to a comfor...

Страница 19: ...s Ensure that the batteries are installed in the proper direction as per the markings shown in the battery tray If the batteries were already installed before changing the hardware setup options chang...

Страница 20: ...s the OK button With the day flashing press UP or DOWN to set the day of the week Press NEXT and the clock time will start flashing Use UP or DOWN to set the time making sure the AM PM indication is c...

Страница 21: ...ngle press of the EMER button again will end Emergency Heat and return back to normal Heat mode If a power loss occurs while in Emergency Heat mode the thermostat will continue to remain in Emergency...

Страница 22: ...her HEAT MODE or COOL MODE MINIMUM RUN TIME The thermostat has a default internal time delay of 5 minutes between load on and load off activations to prevent heating or cooling system damage which can...

Страница 23: ...he OK button to enter the programming screen Use the UP and DOWN buttons to adjust the start time for the MORN period then press the NEXT button to advance Use the UP and DOWN buttons to adjust the se...

Страница 24: ...r as the thermostat will timeout and automatically exit these adjustment screens after approximately 10 seconds without a button press SWING DESCRIPTION A thermostat works by turning your heating or c...

Страница 25: ...umber of degrees from the set point that will be required for the second heating stage to turn on This setting can be used to conserve energy in situations where the second heating stage is more costl...

Страница 26: ...d DOWN buttons to change the number value between 0 F and 9 F degrees 0 C to 5 C The 0 zero degree setting will disable the 2nd heating stage while in regular Heat mode Press the NEXT button to accept...

Страница 27: ...t to OVERRIDE TEMPERATURE Use the UP and DOWN buttons to select your desired Set Temperature that will be used during the Setback duration Once complete press the NEXT button to accept the setting and...

Страница 28: ...WRONG CODE will flash briefly and you may try to enter the correct code again If the current code has been entered correctly you will have the ability to change the desired Temp Stop Lock Code to some...

Страница 29: ...r at the top of the screen Press OK to proceed with entering the unlock code or press the EXIT button to cancel The words ENTER CODE will appear at the top of the screen along with four digits at the...

Страница 30: ...n time hours can elapse before showing CHANGE FILTER in the Normal Run screen The adjustment range for this setting is from 0 hours to 2000 hours with 720 hours as the default A filter limit setting o...

Страница 31: ...EXIT button to return to the Normal Run screen HARDWARE RESET The Hardware Reset button labeled HW RST is a small round push button that is located towards the right side of the circuit board just bel...

Страница 32: ...modes of operation will be disabled for 5 minutes After the 5 minute duration has expired the thermostat will return to normal operation automatically This thermostat is powered by two AA Alkaline ba...

Страница 33: ...rs from the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective...

Страница 34: ...34 Philadelphia PA 19112 www luxproducts com 856 234 7905 LUX MENU F F SET PM HEAT OFF COOL AUTO ON FAN...

Отзывы: