JUMPER Settings
There are 2 Basics steps involving jumper settings:
1.
Move the Jumper to the
appropriate position as
described below.
2.
After making all the jumper
selections, press the Reset
(RST)
button.
HORZ
:
Sets the thermostat in a Horizontal orientation.
VERT
:
Sets the thermostat in a Vertical orientation
.
Multiple Features can be accessed and selected by navigating through
the MENU screen. The instructions below detail all the options under the
MENU screen
:
a. CAL: Calibration
b. SWNG: Temperature Swing
c. DELY: Delay
d. F/C: Fahrenheit and Celsius Selection
e. TLMT: Temperature Limit
f. TEST: Test Mode
g. EXIT: Exit
1.
Access the Menu Screen
: In the off position, press Up and Down
simultaneously
(approx. 3 seconds) until the MENU screen is displayed
MENU
1.
Press and
h
old the Up and Down button simultaneously at the CAL
selection.
2.
Press Up or Down to select the Calibration amount (-5F to +5F
increments)
3.
Once the desired calibration point is reached, press and hold the Up
and Down button simultaneously to select the
value
CALIBRATION
1.
Press and
h
old the Up and Down button simultaneously at the
SWNG
selection.
2.
Press Up or Down to select the
Swing setting
(
0.25 to 2.25
increments)
3.
Once the desired
swing
point is reached, press and hold the Up
and
Down button simultaneously to select the
value
TEMPERATURE SWING
1.
Press and
h
old the Up and Down button simultaneously at the
DELY
selection.
2.
Press Up or Down to select the
5 Minute or 2 Minute Compressor
delay
3.
Once the desired
delay
point is reached, press and hold the Up
and
Down button simultaneously to select the
value
COMPRESSOR DELAY