background image

3

1. When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the

terminal block while the screw is being tightened.

2. Securely tighten all of the electrical terminal screws, including any unused ones.  Be careful not to over tighten the

screws, they only need to be snug.

** Complete heating and/or cooling system wiring can be found in the WIRE IDENTIFICATION AND WIRING
SCHEMATICS section of this instruction sheet.  The schematics shown provide component information for brand
new installations or for unreferenced wires.

On the circuit board, there are hardware settings called “jumpers”.  These settings can be changed from their default
values by removing its black cap and reinstalling the cap so that it is positioned
on only one (1) of the metal pins, and not both.  A CLOSED jumper means the
black cap is on both of the metal pins, and an OPEN jumper means the cap is on
only one (1) metal pin.

HARDWARE RESET BUTTON:

A change to ANY of the jumper settings will not be

recognized by the thermostat until the white HARDWARE RESET button on the
circuit board is pressed.

JP1 (SYSTEM):

[CLOSED = Furnace, default] This setting is used for the majority of all heating

systems that are not heat pumps.  Examples for this setting would be: natural gas furnace, hot
water baseboard heat, and oil heat.  [OPEN = Heat Pump] Use this setting if you have a heat
pump unit (which looks just like an outside air conditioning unit, but is used for both cooing and
heating).

JP2 (DELAY):

[CLOSED = 5 Minutes, default] This setting changes the length of time that the

system must remain either on or off before it will switch to the alternate on or off state. The
main purpose of this setting is to provide equipment protection by preventing brief or undesirable
frequent on/off cycling. [OPEN = 2 Minutes] This can be used to decrease the minimum amount
of time that occurs between cycles, and may be desired for hot water radiator systems to reduce
overshoot.

JP3 (SCALE):

[CLOSED = Fahrenheit, default] All temperature values are displayed in F˚ degrees.

[OPEN = Celsius] This setting displays all temperature values in C˚ degrees.

JP4 (FAN):

This option is located separately from the first three settings shown above.

[CLOSED = Gas, default] This setting lets the heating system itself control the blower fan
automatically.  Types of systems that would typically use the “Gas” fan setting would be: natural
gas furnace, propane furnace, and oil furnace.

[OPEN = Elec] This setting runs the system’s blower fan when heat is called for, and is required
for systems that do not control their own fan while in HEAT mode.  Heat pump systems, and units
with an electric heating element typically require this setting.

CLOSE

Furnace

5 MIN

F

OPEN

HP

2 MIN

C

JP1
JP2
JP3

WIRING TERMINAL CONNECTIONS:

SYSTEM CONFIGURATION AND SETUP OPTIONS:

O P E N

C L O S E D

E L E C T

G A S

Содержание PSDS11b

Страница 1: ... WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Procter Gamble Company LUX Products Corporation Mt Laurel New Jersey 08054 http www luxproproducts com SYSTEM COMPATIBILITY 1 Stage Heat 1 Stage Cool Electronic Accuracy Innovative SAVE Feature Gas Elec Fan Option Battery Powered O...

Страница 2: ...ally left open 3 Do not locate the thermostat where unusual heating or cooling conditions may be present such as direct sunlight above a lamp television or radiator or on a wall next to an exterior door or window 4 Do not locate in a damp environment as this can lead to corrosion that may shorten thermostat life 5 If painting or construction work is still ongoing cover the thermostat completely or...

Страница 3: ... heat and oil heat OPEN Heat Pump Use this setting if you have a heat pump unit which looks just like an outside air conditioning unit but is used for both cooing and heating JP2 DELAY CLOSED 5 Minutes default This setting changes the length of time that the system must remain either on or off before it will switch to the alternate on or off state The main purpose of this setting is to provide equ...

Страница 4: ... 5F 3 C degrees while in Heat mode or raise the set temperature by 5 F 3 C degrees while in Cool mode When you leave the house simply press the SAVE button one time to put the thermostat into Save mode and the word SAVE will be shown on the screen When you return home press the SAVE button again to cancel the Save mode and return back to the previous set temperature that you were using originally ...

Страница 5: ...ent by as much as plus or minus 5 F 3 C degrees from its original value 0 F 0 C is the default setting To adjust the Calibration setting Set the thermostat to OFF mode using the System Mode switch press both the UP and DOWN together for at least 2 seconds When the screen changes to a single digit this is the current Calibration setting value and it can be adjusted using the UP or DOWN buttons The ...

Страница 6: ...om the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective units to the location from which the purchase was made along with proof of purchase Please refer to TECHNICAL ASSISTANCE before returning thermostat Purchaser assumes all risks and liability for incidental...

Страница 7: ...mostat location they are located with your heating and cooling equipment 4 For Heat Pumps use the B or O wire NOT BOTH Typically neither are used in a conventional system 5 If Y and C wires are both present then C is a common wire 6 If you have a B wire in your system which is used as a common wire connecting it to the B terminal on this thermostat may damage your system and or the thermostat W1 4...

Страница 8: ...AGE COOLING WITH TWO SEPARATE 24V TRANSFORMERS Factory RH RC Jumper Wire REMOVED FAN COMMON HEATER AIR CONDITIONER 5 6 WIRES BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC 24V HEAT POWER 24V COOL POWER 5 X C F G FAN O B Use O or B Terminals Never Both RC V R Y1 6 Y G Y O B W RH RC SINGLE STAGE HEAT PUMP SYSTEM WITH NO AUX OR EMERGENCY HEAT Factory RH RC Jumper Wire 24V...

Отзывы: