background image

3

TYPICAL SINGLE-STAGE

HEAT PUMP WIRING

Figure 12

110

G

Y

W RH

B

O

RC

COMP

FAN

24 VAC HEAT

TRANSFORMER

CHG.

OVER

ADD

JUMPER

BETWEEN

Y & W

ALT.

110

TYPICAL COOLING AND

HEATING SYSTEM

(5-WIRE)

FAN

COOL

COMP

GAS

VALVE

24 VAC HEAT

TRANSFORMER

110

Figure 11

24 VAC COOL

TRANSFORMER

REMOVE

JUMPER

BETWEEN

RH & RC

G

Y

W RH

RC

O

B

TYPICAL COOLING AND

HEATING SYSTEM

(4-WIRE)

Figure 10

110

GAS

VALVE

COOL

COMP

FAN

24 VAC HEAT

TRANSFORMER

G

Y

W RH

RC

O

B

TYPICAL HOOKUP FOR 3-WIRE

HEAT SYSTEM IF THIRD

WIRE IS FAN WIRE

Figure 9

GAS

VALVE

110

FAN

24 VAC

TRANSFORMER

G

Y

W RH

RC

O

B

TYPICAL HOOKUP FOR 2-WIRE

24V HEATING SYSTEM AND

MILLIVOLT SYSTEM

Figure 8

GAS

VALVE

110

24 VAC

TRANSFORMER

OR

THERMOPILE

G

Y

W RH

RC

O

B

These diagrams below are provided for new installations or unreferenced wires. 

N O T E

If you have an electric system and the blower does not operate after installation, find the factory installed

yellow wire currently attached to the “Y” terminal and move it to the “A” terminal on the sub-base.

Содержание LUXPRO PSM40SA

Страница 1: ... Do not install until all construction work and painting have been completed 2 TOOLS REQUIRED Wirestripper or knife drill with 3 16 bit screwdriver level and a pencil 3 REMOVING OLD THERMOSTAT Please read all instructions carefully As you complete each step check the adjoining square Disconnect electricity and turn off gas to the heater Remove cover from old thermostat Disconnect wires from thermo...

Страница 2: ...R VALVE POWERED IN COOL COOL TRANSFORMER If both Y and C wire are present tape off C wire Heating Cooling Systems 4 or 5 Wire with One Transformer G Y W RH B O RC C Y G F W V R R C B O Optional Optional Tape Off TC FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE POWERED IN HEAT DAMPER OR CHANGEOVER VALVE POWERED IN COOL COOL TRANSFORMER If both Y and C w...

Страница 3: ...N 24 VAC HEAT TRANSFORMER G Y W RH RC O B TYPICAL HOOKUP FOR 3 WIRE HEAT SYSTEM IF THIRD WIRE IS FAN WIRE Figure 9 GAS VALVE 110 FAN 24 VAC TRANSFORMER G Y W RH RC O B TYPICAL HOOKUP FOR 2 WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM Figure 8 GAS VALVE 110 24 VAC TRANSFORMER OR THERMOPILE G Y W RH RC O B These diagrams below are provided for new installations or unreferenced wires N O T E If you h...

Страница 4: ...ur convenience Place Base Figure 3 over Sub Base and attach by tightening three captive screws Fasten loosely to wall using two mounting screws Place a level against the bottom of the Base adjust until it is level and then tighten mounting screws to secure Find anticipator setting on old thermostat Setting on new thermostat should be the same Do this by carefully sliding the long pointer Figure 2 ...

Отзывы: