background image

7

RC

V

R

Y1

6

Y

F

G

G

Y

O

B

W

RH

RC

1-STAGE, COOLING ONLY

Factory RH-RC Jumper Wire Installed

FAN

24V

POWER

COMMON

AIR

CONDITIONER

3, 4 WIRES

BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC

2

X

C

WIRING DIAGRAM NOTES:

1. The BOLD lines are what you should be connecting to the terminals on this new thermostat.

2. The DASHED lines are optional depending upon your system type.

3. In many cases, the thin lines shown as “SYSTEM COMMON” will not be visible at the thermostat

location, they are located with your heating and cooling equipment.

4. For Heat Pumps, use the “B” or “O” wire, NOT BOTH. Typically neither are used in a conventional

system.

5. If “Y” and “C” wires are both present, then “C” is a common wire.

6. If you have a “B” wire in your system which is used as a common wire, connecting it to the “B”

terminal on this thermostat may damage your system and/or the thermostat.

W1

4

W

RH

V

R

F

G

G

Y

O

B

W

RH

RC

HEATING ONLY (INCLUDING MILLIVOLT)

(2-WIRE HEAT USE “RH” & “W”)

Factory RH-RC Jumper Wire Installed

FAN

24V

POWER

COMMON

HEATER

2, 3, 4 WIRES

BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC

FAN WIRE

MAY NOT BE

PRESENT IN

ALL SYSTEMS

1

X

C

Содержание DMH110b

Страница 1: ... WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Procter Gamble Company LUX Products Corporation Mt Laurel New Jersey 08054 http www luxproducts com SYSTEM COMPATIBILITY 1 Stage Heat 1 Stage Cool Electronic Accuracy Innovative SAVE Feature Gas Elec Fan Option Battery Powered Only...

Страница 2: ...ally left open 3 Do not locate the thermostat where unusual heating or cooling conditions may be present such as direct sunlight above a lamp television or radiator or on a wall next to an exterior door or window 4 Do not locate in a damp environment as this can lead to corrosion that may shorten thermostat life 5 If painting or construction work is still ongoing cover the thermostat completely or...

Страница 3: ... heat and oil heat OPEN Heat Pump Use this setting if you have a heat pump unit which looks just like an outside air conditioning unit but is used for both cooing and heating JP2 DELAY CLOSED 5 Minutes default This setting changes the length of time that the system must remain either on or off before it will switch to the alternate on or off state The main purpose of this setting is to provide equ...

Страница 4: ... 5F 3 C degrees while in Heat mode or raise the set temperature by 5 F 3 C degrees while in Cool mode When you leave the house simply press the SAVE button one time to put the thermostat into Save mode and the word SAVE will be shown on the screen When you return home press the SAVE button again to cancel the Save mode and return back to the previous set temperature that you were using originally ...

Страница 5: ...ent by as much as plus or minus 5 F 3 C degrees from its original value 0 F 0 C is the default setting To adjust the Calibration setting Set the thermostat to OFF mode using the System Mode switch press both the UP and DOWN together for at least 2 seconds When the screen changes to a single digit this is the current Calibration setting value and it can be adjusted using the UP or DOWN buttons The ...

Страница 6: ...m the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective units to the location from which the purchase was made along with proof of purchase Please refer to TECHNICAL ASSISTANCE before returning thermostat Purchaser assumes all risks and liability for incidental ...

Страница 7: ...mostat location they are located with your heating and cooling equipment 4 For Heat Pumps use the B or O wire NOT BOTH Typically neither are used in a conventional system 5 If Y and C wires are both present then C is a common wire 6 If you have a B wire in your system which is used as a common wire connecting it to the B terminal on this thermostat may damage your system and or the thermostat W1 4...

Страница 8: ...AGE COOLING WITH TWO SEPARATE 24V TRANSFORMERS Factory RH RC Jumper Wire REMOVED FAN COMMON HEATER AIR CONDITIONER 5 6 WIRES BLACK TERMINAL LETTERS ARE TYPICAL GRAY TERMINAL LETTERS ARE BRAND SPECIFIC 24V HEAT POWER 24V COOL POWER 5 X C F G FAN O B Use O or B Terminals Never Both RC V R Y1 6 Y G Y O B W RH RC SINGLE STAGE HEAT PUMP SYSTEM WITH NO AUX OR EMERGENCY HEAT Factory RH RC Jumper Wire 24V...

Отзывы: