background image

 

StarEye Maxi 

p.3/18 

LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM 

T: +32 3 293 35 50 – F: +32 3 293 35 44 

www.lux-lumen.com 

1

 

Picture 

1.1

 

General 

 

StarEye Maxi spot with bracket 

 

 

StarEye Maxi spot with bracket and snoot 

 

Содержание 10656

Страница 1: ...StarEye Maxi 10656 Integrated step down convertor ...

Страница 2: ...D BURNS 6 3 4 PROTECTION FROM INJURY 7 3 5 DISPOSING OF THIS PRODUCT 7 4 PHYSICAL INSTALLATION 8 4 1 UNPACKING 8 4 2 LOCATION AND ORIENTATION 8 4 3 MOUNTING 8 5 EXTERNAL CONNECTIONS 10 5 1 DC POWER INPUT 10 6 EMC AND SAFETY REQUIREMENTS 11 7 INSTALLATION SETUP 12 7 1 SPECIFICATION 12 8 SERVICE AND MAINTENANCE 13 8 1 SAFETY PRECAUTIONS 13 8 2 CLEANING 13 8 3 CHANGING LENSES 14 9 WARRANTY 15 9 1 APP...

Страница 3: ...Maxi p 3 18 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 1 Picture 1 1 General StarEye Maxi spot with bracket StarEye Maxi spot with bracket and snoot ...

Страница 4: ...StarEye Maxi p 4 18 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 2 Dimensions ...

Страница 5: ... you read this manual and ensure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led unit only as described in this manual and in conformity with local regulations If you have any questions how to operate this product safely please contact your point of sale 3 1 Symbols Following symbols are used to identify important safety...

Страница 6: ...ocal regulations Please ensure yourself that the AC to DC power supply is able to deliver the rated current requirements of the installation If any cable seal or housing is damaged cracked or reformed disconnect the power of the installation immediately For any additional servicing not described in this manual please contact your point of sale 3 3 Protections from fire and burns Do not operate thi...

Страница 7: ...ts accessories are securely fastened Verify that the led unit is firmly fixed to its supporting underground 3 5 Disposing of this product This led lighting device is manufactured in compliance with directive of the European community waste electrical and electronically equipment Please help to preserve our environment and ensure that this product will be recycled properly at the end of its life ...

Страница 8: ...ure yourself that there is sufficient and unrestricted air flow around the StarEye Maxi led unit 4 1 Unpacking The following items are included in your package LED fixture complete with focussing bracket Protective antistatic packaging with short form manual 4 2 Location and orientation This led unit can be used in all directions 4 3 Mounting Surface mounting The StarEye Maxi led unit can be mount...

Страница 9: ...red PWM power supply s OT 80 220 240 24 DIM P 80W 24vDC Max StarEye Maxi spots 7pcs Ordercode 30958 MEAN WELL PWM 90 24 90W 24vDC Max StarEye Maxi spots 8pcs Ordercode 24162 OT 120 220 240 24 DIM P 120W 24vDC Max StarEye Maxi spots 10pcs Ordercode 30959 OT 240 220 240 24 DIM P 240W 24vDC Max StarEye Maxi spots 20pcs Ordercode 30960 Preferred PWM LED drivers 6 channel DMX PWM LED driver Max StarEye...

Страница 10: ...tor positive Black inner conductor negative Improper connection might damage the StarEye Maxi led unit and power supply permanently In case of inversed polarity the warranty is void Power supply Rated voltage The rated input voltage range of the StarEye LED fixture is 24 volt DC Due to the use of a step down convertor integrated in the housing a highly efficient system is created Cable Please ensu...

Страница 11: ... 2007 Radiated immunity test EN 61000 4 4 2004 Fast transients and burst immunity EN 61000 4 5 2005 Surge immunity test EN 61000 4 6 2008 Conducted immunity test EN 61000 4 8 1993 Magnetic field immunity test EN 61000 4 11 2004 Voltage variations immunity test EN 61000 6 1 2005 Generic standards for immunity Emission according to EN 61000 3 2 2005 A1 2008 A2 2009 Harmonics emission test 16A EN 610...

Страница 12: ...put Weight 300 gr Different lenses are possible o Spot 22 o Medium 26 o Wide 48 o Ultra wide 60 Different colors are possible o Warm White 2700K CRI 80 Efficacy 100 lm W o Warm White 3000K CRI 80 Efficacy 105 lm W o Neutral White 4000K CRI 80 Efficacy 110 lm W o Cold White 5700 CRI 80 Efficacy 120 lm W RAL colors are not available The ingress protection of the StarEye Maxi led unit is IP20 The dim...

Страница 13: ...re system and allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The StarEye Maxi led unit itself Extensive dirt and particle build up degrades performance may cause overheating can result in damaged led unit and power supply s Damage by inadequate cleaning or maintenance is not covered by the product warranty Never use solvents to clea...

Страница 14: ...ing Lenses Step 1 Screw the front cover counterclockwise to remove it from the led unit Step 2 Take out the old lens Don t touch the LED itself to avoid damage to the StarEye Maxi Step 3 Insert the new lens into the led unit Step 4 Screw the front cover onto the housing clockwise Do not displace the rubber band to prevent fluid ingress ...

Страница 15: ...tment will be borne by the customer Limitations Lux Lumen will not warrant the following Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any software Defects caused by modifications carried out without Lux Lumen s approval Damage resulting from the fact that a product is not conforming to country specific standards or specifications in anot...

Страница 16: ...h this product Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond the control of Lux Lumen including but not limited to lightning water fire public disturbances improper ventilation and acts of god Others It is the responsibility of the customer to backup and save ...

Страница 17: ...l The procedure to obtain a RMA Step 1 Customer contacts Lux Lumen about warranty defects if material has to be returned Step 2 Lux Lumen sends the customer a filled out RMA document using a unique RMA number Step 3 Customer sends material include a copy of the RMA document with the material Step 4 Lux Lumen evaluates the problem and informs the client if repair is done under warranty or makes an ...

Страница 18: ... WILRIJK BELGIUM T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 10 Used list of abbreviations AC Alternating current DC Direct current F Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode CRI Color Rendering Index ...