8
0697-551 No
zzles - 03/2021
en
The conductive connection between the full and
empty containers is achieved by means of a conduc-
tive substrate (e.g. conductive gratings).
The transition between container and earthing must
also be conductive.
Fig. 1
Legend:
(1) Equipotential bonding cable, (2a) conductive
substrate or connection of an equipotential bond
-
ing cable to both drums, (2b) galvanic connection
(low contact resistance to earth), (3) conductive
hose, (4) conductive connection between hose
and hose connector, (5) pump tube for zone 0, (6)
motor with inaccessible metal parts, (7) Nozzle
3. Transport and storage
3.1 Transport
Unpacking and checking condition of delivery
►
Unpack the nozzle on receipt and check for
transport damages.
►
Report transport damages to the manufacturer
immediately.
►
Check that the consignment is complete as
ordered.
3.2 Storage
►
Store the nozzle in a dry place, protected from
the weather and UV-rays.
►
After use, keep the nozzles PP, PVDF and SS on
the suspension hook (
→
Fig. 2, pos. 1).